(2)
Online self-diagnostics (SEND DIAGNOSTIC command)
The INIT can make the HDD execute self-diagnostics by issuing the SEND DIAGNOSTIC
command.
The INIT specifies the execution of self-diagnostics by setting 1 for the SelfTest bit on the CDB in the
SEND DIAGNOSTIC command and specifies the test contents with the UnitOfl bit.
When the UnitOfl bit on the CDB is set to 0, the HDD executes the hardware function test only
once. When UnitOfl bit is set to 1, the HDD executes the hardware function test, seek (positioning)
test, and data write/read test for the Internal test space only once.
a. Error recovery during self-diagnostics
During the self-diagnostics specified by the SEND DIAGNOSTIC command, when the
recoverable error is detected during the seek or the write/read test, the HDD performs the error
recovery according to the MODE SELECT parameter value (read/write error recovery
parameter, additional error recovery parameter) which the INIT specifies at the time of issuing
the SEND DIAGNOSTIC command.
PER
0
1
b. Reporting result of self-diagnostics and error indication
When all specified self-diagnostics terminate normally, the HDD posts the GOOD status for the
SEND DIAGNOSTIC command.
When an error is detected in the self-diagnostics, the HDD terminates the SEND
DIAGNOSTIC command with the CHECK CONDITION status.
When the CHECK CONDITION status is posted, sense data contains detailed information on
the error detected by the initial self-diagnostics.
The HDD status after the CHECK CONDITION status is posted differs according to the type of
the detected error.
a)
When an error is detected in the seek or write/read test, the subsequent command can be
accepted correctly. When the command other than the REQUEST SENSE is issued from
the same INIT, the error information (sense data) is cleared.
C141-E222
Operation of self-diagnostics
The self-diagnostics continues when the error is recovered. The self-
diagnostics terminates normally so far as the unrecoverable error is not
detected.
The self-diagnostics continues when the error is recovered. If the
unrecoverable error is not detected, the consecutive tests are executed till last
test but the self-diagnostics terminates with error. The error information
indicates that of the last recovered error.
6.1 Diagnostics
6-3