Hardware Monitor - Fantom Drives MGT-08SC08A Installation Reference Manual

Raid scsi to s-ata
Table of Contents

Advertisement

3.10.3 Hardware Monitor

To view the RAID subsystem controller's hardware monitor information, move the
mouse cursor to the main menu and click the Hardware Monitor link. The Hard-
ware Information screen appears.
NOTE: When no disk drive is installed in the disk slot, the disk temperature
will show "—". The disk temperature will also show "—" when "HDD SMART
Status Polling" is disabled in System Configuration.
The Hardware Monitor Information provides the temperature and voltage of the
internal RAID subsystem. All items are also unchangeable. The warning messages
will indicate through the LCD, LED and alarm buzzer.
Item
Controller Board Temperature
HDD Temperature
Power Supply +12V
Power Supply +5V
Power Supply +3.3V
DDR Supply Voltage +2.5V
CPU Core Voltage +1.3V
DDR Termination Power +1.25V
Warning Condition
> 60 Celsius
> 55 Celsius
< 10.5V or > 13.5V
< 4.7V or > 5.4V
< 3.0V or > 3.6V
< 2.25V or > 2.75V
< 1.17V or > 1.43V
< 1.125V or > 1.375V
RAID Configuring
3-53

Advertisement

Table of Contents
loading

Table of Contents