Connection instructions
The T3 Inverter heat pump has an internal source pump.
T3 Inverter
Gemini Inverter
The Gemini Inverter heat pump has two cooling modules.
The lower module has an inverter controlled compressor
with an internal source pump. The upper module has an
on-off compressor that does not have an internal source
pump. Instead, the pump is installed outside the device.
Install the source pump in the return pipe of the collector
circuit near the heat pump, between the shut-off valve and
the heat pump according to the installation instructions of
the pump. See Electrical connection under Electrical
connections -> Connecting an external source pump.
26
The external (standard) source pump is included in the
standard delivery of the heat pump.
Install the heat source pump (GP16) according to the
installation instructions of the circulator pump near the
return pipe (EP14-XL6) and (EP15-XL6) of the collector
circuit,
between
and
the
shut-off
The heat source pump is not included in the delivery in
certain
countries (see the delivery note).
Gebwell T3 Inverter | Gemini Inverter installation manual
the
heat
pump
valve
(see
the
figure).