Remote Control Button - Panasonic CS-PZ35TKE Service Manual

Hide thumbs Also See for CS-PZ35TKE:
Table of Contents

Advertisement

16.2.2
Operation mode during Heating only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation Mode
After 30s sampling, regardless of the indoor intake or
AUTO
outdoor intake temperature judgment, the unit will run
Heating operation.
HEAT
The unit will run Heating operation.
COOL
The unit will stop and Power LED blinking.
DRY
The unit will stop and Power LED blinking.
NANOE-G
The unit will stop and Power LED blinking.
Stand-alone
The unit will run Force Cooling Operation for X_CTRYTM [15]
Force Cooling
minutes
Force Heating The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto Operation. After
AUTO
30s sampling, regardless of the indoor intake or outdoor intake
(with Timer)
temperature judgment, the unit will run Heating operation.
HEAT
The unit will turn ON by the timer and run Heating Operation.
(with Timer)
COOL
The unit will not turn ON by the timer. Power LED blinking.
(with Timer)
DRY
The unit will not turn ON by the timer. Power LED blinking.
(with Timer)
Cooling
The unit will stop and Power LED blinking.
Test Mode
Heating
The unit will operate according to specify Heating test mode
Test Mode
operation parameter.

16.3 Remote Control Button

16.3.1
SET Button
To check remote control transmission code and store the transmission code to EEPROM:
Press "Set" button by using pointer.
o
Press "Timer Set" button until a "beep" sound is heard as confirmation of transmission code changed.
o
To limit set temperature range for COOL & DRY, HEAT mode.
Press "Set" button by using pointer.
o
Press TEMP increment or decrement button to choose No. 3.
o
Press Timer increment or decrement button to select desired temperature low limit of set temperature for
o
COOL & DRY mode.
Press Timer Set button to confirm low limit selection.
o
Press TEMP increment or decrement button to choose No. 4.
o
Press Timer decrement or increment button to select desired temperature high limit of set temperature for
o
COOL & DRY mode.
Press Timer Set button to confirm high limit selection.
o
Press TEMP increment or decrement button to choose No. 5.
o
Press Timer increment or decrement button to select desired temperature low limit of set temperature for
o
HEAT mode.
Press Timer Set button to confirm low limit selection.
o
Press TEMP increment or decrement button to choose No. 6.
o
Press Timer decrement or increment button to select desired temperature high limit of set temperature for
o
HEAT mode.
Press Timer Set button to confirm high limit selection.
o
LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel
o
button.
16.3.2
RESET (RC)
To clear and restore the remote control setting to factory default.
Press once to clear the memory.
o
Heating Only Operation Mode Activated
Heating Only Operation Mode Deactivated
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting and
Indoor Intake Sensor (New Auto Mode) or Outdoor
Intake Sensor (Old Auto Mode).
The unit will run Heating operation.
The unit will run Cooling operation.
The unit will run Cooling Dry operation.
The unit will run Nanoe-G Stand-alone operation.
The unit will run Force Cooling operation.
The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto Operation. After
30s sampling, the unit will judge the operation mode base on
remote controller temperature setting and Indoor Intake Sensor
(New Auto Mode) or Outdoor Intake Sensor (Old Auto Mode).
The unit will turn ON by the timer and run Heating Operation.
The unit will turn ON by the timer and run Cooling Operation.
The unit will turn ON by the timer and run Cooling Dry
Operation.
The unit will operate according to specify Cooling test mode
operation parameter.
The unit will operate according to specify Heating test mode
operation parameter.
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents