High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed this caution may result in electric shocks.
18.2 CS-PZ50TKE
18.2.1
Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal
Procedures
18.2.1.1
To Remove Front Grille
2.
Remove 2 caps and 2 screws at the
bottom of discharge vane.
18.2.1.2
To Remove Electronic Controller
WARNING
Figure 1
4.
Remove the control board
cover by releasing 2 hooks.
Figure 2
136
3.
Hold both sides of the front grille and
remove it by pulling up and toward
you gently.
1.
Lift to open the vertical vane
and make intake grille gently.
2 Hooks