Flow Factors Meter 1
Flow factors are the K and offset for each meter, used to determine the flow rate in gallons per minute or liters per minute from the raw pulse
rate of the meter. Flow factors are determined by the pipe size and type.
Enter/edit the K factor associated with the flow metering device being used. The K factor may be found in the specification sheet for the
flow meter. The Offset factor may be found in the specification sheet for the flow meter.
1
2
N/O Master
(1 Field to set)
Configure the master valve/pump start output for either normally OPEN or normally CLOSED operation.
1
2
(4 Fields to set: K and Offset X whole and decimal values)
3
K =
Offset =
ENTER
- OR -
3
ENTER
- OR -
Flow Factors Meter 1
0003.000
1.000
4
** SAVED! **
K =
0003.000
Offset =
ENTER
- OR -
4
ENTER
- OR -
1.000
13