Advertisement

Network VP
User's Guide
• 16 to 64 stations in eight-station increments
• Field programmable for future upgrades
• Does not require EPROM(s) replacement
• Operates as a stand-alone controller or under
the management of a central computer.
• Supports wireline or radio communications
with the central computer
• Supports hybrid communication (wireline
and radio) for increased flexibility and cost
effectiveness
• 64 irrigation programs:
• Independent stand-alone and central
operation
• Basic, Advanced and Grow-In programs with
unique capabilities to meet your needs
• Multi-Manual, Program Start and Syringe
manual operations
• Operates up to 32 stations simultaneously
• Backwards compatible with Network 8000
TM
4.00 Satellite

Advertisement

Table of Contents
loading

Summary of Contents for Toro Network VP 4.00 Satellite

  • Page 1 Network VP 4.00 Satellite User’s Guide • 16 to 64 stations in eight-station increments • Field programmable for future upgrades • Does not require EPROM(s) replacement • Operates as a stand-alone controller or under the management of a central computer. •...
  • Page 2: Table Of Contents

    Index Radio Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Fuse and Circuit Breaker Specifications - - - - - - - - - - - - - - - - Satellite Controller Specifications- - - - - - - - - - - - - - - - - - - - - Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Modes of Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -...
  • Page 3: Radio Specifications

    Radio Specifications Equipment Type – Data radio, MAXON, model SD-125 U2 Frequency Band – UHF RF Output Power – 2.0 watt Current Consumption: Standby (Muted) – < 65 mA Transmit 2 watts RF power – < 1.0A FCC License: FCC ID# MNT-PC-UC Fuse &...
  • Page 4: Introduction

    Introduction The Toro Network VP Satellite combines modular flexibility, ease of use and increased programmability in a single controller. Modularity means flexibility. The Network VP is available from 16 to 64 stations, and can expand in eight-station increments to meet your needs. Optional station switch capability and surge protection provide simple operation and added security.
  • Page 5: Timing Mechanism Components

    Timing Mechanism Components Left and Right Arrows allow you to select the atellite etwork next entry field within the same entral ocal menu line. Any changes will be saved after you exit that entry field. Up and Down Arrows allow you to scroll up and down through the menu items.
  • Page 6: Distribution Board Components

    Distribution Board Components 5V, 9V and 12V LED Indicator - When illuminated, the LED indicates the presence of the corresponding voltage in the satellite’s circuitry. GND, 12V, 9V and 5V Sources - Voltage source pins provide terminals for monitoring the satellite’s internal voltages with the use of a digital multi-meter or an oscilloscope.
  • Page 7: Pump / Common Board Components

    Pump / Common Board Components Pump Terminal Switch - The Pump terminal can be placed in PUMP COMMON ON, OFF or Auto with this switch. AUTO Common Terminal Switch - The Common terminal can be placed in ON, OFF or Auto with this switch. PUMP COMMON PUMP...
  • Page 8: Power-Up Diagnostics

    Power-Up Diagnostics Upon power-up, the satellite will display: Network VP Booting The Network VP Satellite will initiate a diagnostic test automatically during power-up. This function will take approximately ten seconds and it can not be bypassed. If a problem is detected during the diagnostic test, it will be indicated on the display.
  • Page 9: Start Key

    If the satellite has an active running program, the display will read: Sun 04/02/06 02:31 pm Sat# 001-001 Sec: 57 Running 04 prg+ Man (Running Multi-Manual) P01 Sta01 %00:05:00 (The “%” symbol before the runtime indicates that station 01 is percent adjusted.) P01 Sta02 00:05:00 (P01 indicates Program 01 is currently active)
  • Page 10: Pause / Resume Key

    Pause / Resume Key The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause duration. Pause / Resume Function Directions Pause function example: Program 01 has been manually activated. Pause program 01 for 30 minutes. 1.
  • Page 11: Stop Key

    Pause All All currently running programs, multi-manual and syringe will be suspended until the pause time-out expires. New start is allowed only for Manual functions. Additional programs that are scheduled to start while Pause All is in effect will be stacked until the Pause time-out expires.
  • Page 12: Satellite Settings

    Satellite Settings Satellite Settings allows you to set satellite parameters such as Time, Date and Language. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
  • Page 13 Setup Amps: – Use this menu item to establish and update each of the stations’ nominal current value to the satellite’s memory. These values are used by the satellite for Current Reaction Management (CRM) and Current Prediction Management (CPM). CRM allows the Network VP 3.0 to react to an out-of-tolerance current condition. This condition occurs when a station’s electrical current exceeded the boundaries of the tolerance setting for that station.
  • Page 14: Station Settings

    Station Settings Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
  • Page 15 Edit Name: – Use this menu item to assign a name description to the station. The naming format is XX-AA- YY, where XX represents the golf course hole number, AA represents the area description acronym and YY represents the sprinkler number within the area. By following the naming format, you can easily figure out where and what area the station is watering.
  • Page 16: Scheduled Watering

    Scheduled Watering The Network VP satellite features 64 fully-independent resident programs. With three types of programs to select from, you can further custom fit your irrigation programs to any landscape. • Basic Irrigation Program will activate a station or group of stations with one start time on a daily basis. Each station will water for the duration specified in hours, minutes and seconds.
  • Page 17: Basic Irrigation Program

    Basic Irrigation Program Setting: Basic Irrigation Program example: Create Program 01 with stations 1–5 for 25 minutes each and stations 11–20 for 15 minutes each with a program adjustment of 110%. Set the start time at 6:30 am with five maximum simultaneous active station.
  • Page 18: Advanced Irrigation Program

    Advanced Irrigation Program Setting: Advance Irrigation Program example: Create program 2 with stations 6–10 for 15 minutes each with no percent adjustment. Set the start time 01 at 5:45 am every Monday, Wednesday and Friday only. Set the maximum simultaneous active station to 5. 1.
  • Page 19: Grow-In Irrigation Program

    13. Press the Right Arrow to advance the cursor to the next entry field. This entry field will indicate the runtime in hours, minutes and seconds ( HH:MM:SS). Use the Input Dial and the Right Arrow Key to select the appropriate runtime value. For this example, set the value to 00:15:00. to advance the cursor to the Simult: field.
  • Page 20: Gmm (Group Multi-Manual Function)

    7. Press the Down Arrow to advance the cursor to the Delay: field. This delay time will determine the wait time between program cycles. Use the Input Dial to select the delay time value. Use the Left and Right Arrow Keys to navigate between the Hours and Minutes fields.
  • Page 21: Station Based Flow Management

    5. Press the Down Arrow to advance to the Sta field. Use this field to enter the station numbers that corresponds to the currently displayed sequence. Use the Right and Left arrows to navigate between the station number fields. Use the Input Dial to select station number.
  • Page 22: Manual Watering

    Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program. M-Manual - Select M-Manual to activate a station or group of stations with a specified runtime.
  • Page 23: Manual Syringe

    Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneous stations set in the program still applies. Manual Syringe Activation Directions Syringe activation example: Manually activate all the stations in Program 3 for 2 minutes each. Note: An irrigation program must be configured to activate Manual Syringe.
  • Page 24: (Percent) Adjust

    % (Percent) Adjust The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly, Percent Adjust allows you to tune your system easily without changing all the values in the program. % Adjust Directions 1. Press the % Adjust Key .
  • Page 25 Menu: Station Amps – Use this menu item to review each of the station’s last recorded voltage amperage, nominal amperage value, tolerance value, alarm events, pump nominal amperage value. Use the Input Dial to scroll through the available stations. Use the Down arrow to scroll down to the data fields.
  • Page 26: Troubleshooting Guide

    PUMP COMMON AUTO PUMP COMMON Troubleshooting Guide Power Transformer Pump AC Power Terminals Station Common Output Board WARNING Board HIGH VOLTAGE 115V Electrical Protection 1 - Main Power Switch / 1.5A Circuit Breaker - Protects the controller from a short circuit on the incoming power line.
  • Page 27 Power Distribution Board PUMP COMMON AUTO PUMP COMMON Station Output Board PUMP COMMON DS4 DS5 AUTO PUMP COMMON 5V 9V 12V VP Timing Mechanism LED Indicators 10 - Pump Relay LED Indicator - When illuminated, the pump relay is activated. 11 - Common Relay LED Indicator - When illuminated, the common relay number 1 is activated.
  • Page 28: Lithium Battery Replacement

    Operation in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. © 2010 The Toro Company • Irrigation Division • An ISO-9000-Certified Facility Form Number 373-0324 Rev. E...

Table of Contents