Summary of Contents for Toro Network VP 4.00 Satellite
Page 1
Network VP 4.00 Satellite User’s Guide • 16 to 64 stations in eight-station increments • Field programmable for future upgrades • Does not require EPROM(s) replacement • Operates as a stand-alone controller or under the management of a central computer. •...
Radio Specifications Equipment Type – Data radio, MAXON, model SD-125 U2 Frequency Band – UHF RF Output Power – 2.0 watt Current Consumption: Standby (Muted) – < 65 mA Transmit 2 watts RF power – < 1.0A FCC License: FCC ID# MNT-PC-UC Fuse &...
Introduction The Toro Network VP Satellite combines modular flexibility, ease of use and increased programmability in a single controller. Modularity means flexibility. The Network VP is available from 16 to 64 stations, and can expand in eight-station increments to meet your needs. Optional station switch capability and surge protection provide simple operation and added security.
Timing Mechanism Components Left and Right Arrows allow you to select the atellite etwork next entry field within the same entral ocal menu line. Any changes will be saved after you exit that entry field. Up and Down Arrows allow you to scroll up and down through the menu items.
Distribution Board Components 5V, 9V and 12V LED Indicator - When illuminated, the LED indicates the presence of the corresponding voltage in the satellite’s circuitry. GND, 12V, 9V and 5V Sources - Voltage source pins provide terminals for monitoring the satellite’s internal voltages with the use of a digital multi-meter or an oscilloscope.
Pump / Common Board Components Pump Terminal Switch - The Pump terminal can be placed in PUMP COMMON ON, OFF or Auto with this switch. AUTO Common Terminal Switch - The Common terminal can be placed in ON, OFF or Auto with this switch. PUMP COMMON PUMP...
Power-Up Diagnostics Upon power-up, the satellite will display: Network VP Booting The Network VP Satellite will initiate a diagnostic test automatically during power-up. This function will take approximately ten seconds and it can not be bypassed. If a problem is detected during the diagnostic test, it will be indicated on the display.
If the satellite has an active running program, the display will read: Sun 04/02/06 02:31 pm Sat# 001-001 Sec: 57 Running 04 prg+ Man (Running Multi-Manual) P01 Sta01 %00:05:00 (The “%” symbol before the runtime indicates that station 01 is percent adjusted.) P01 Sta02 00:05:00 (P01 indicates Program 01 is currently active)
Pause / Resume Key The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause duration. Pause / Resume Function Directions Pause function example: Program 01 has been manually activated. Pause program 01 for 30 minutes. 1.
Pause All All currently running programs, multi-manual and syringe will be suspended until the pause time-out expires. New start is allowed only for Manual functions. Additional programs that are scheduled to start while Pause All is in effect will be stacked until the Pause time-out expires.
Satellite Settings Satellite Settings allows you to set satellite parameters such as Time, Date and Language. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
Page 13
Setup Amps: – Use this menu item to establish and update each of the stations’ nominal current value to the satellite’s memory. These values are used by the satellite for Current Reaction Management (CRM) and Current Prediction Management (CPM). CRM allows the Network VP 3.0 to react to an out-of-tolerance current condition. This condition occurs when a station’s electrical current exceeded the boundaries of the tolerance setting for that station.
Station Settings Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
Page 15
Edit Name: – Use this menu item to assign a name description to the station. The naming format is XX-AA- YY, where XX represents the golf course hole number, AA represents the area description acronym and YY represents the sprinkler number within the area. By following the naming format, you can easily figure out where and what area the station is watering.
Scheduled Watering The Network VP satellite features 64 fully-independent resident programs. With three types of programs to select from, you can further custom fit your irrigation programs to any landscape. • Basic Irrigation Program will activate a station or group of stations with one start time on a daily basis. Each station will water for the duration specified in hours, minutes and seconds.
Basic Irrigation Program Setting: Basic Irrigation Program example: Create Program 01 with stations 1–5 for 25 minutes each and stations 11–20 for 15 minutes each with a program adjustment of 110%. Set the start time at 6:30 am with five maximum simultaneous active station.
Advanced Irrigation Program Setting: Advance Irrigation Program example: Create program 2 with stations 6–10 for 15 minutes each with no percent adjustment. Set the start time 01 at 5:45 am every Monday, Wednesday and Friday only. Set the maximum simultaneous active station to 5. 1.
13. Press the Right Arrow to advance the cursor to the next entry field. This entry field will indicate the runtime in hours, minutes and seconds ( HH:MM:SS). Use the Input Dial and the Right Arrow Key to select the appropriate runtime value. For this example, set the value to 00:15:00. to advance the cursor to the Simult: field.
7. Press the Down Arrow to advance the cursor to the Delay: field. This delay time will determine the wait time between program cycles. Use the Input Dial to select the delay time value. Use the Left and Right Arrow Keys to navigate between the Hours and Minutes fields.
5. Press the Down Arrow to advance to the Sta field. Use this field to enter the station numbers that corresponds to the currently displayed sequence. Use the Right and Left arrows to navigate between the station number fields. Use the Input Dial to select station number.
Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program. M-Manual - Select M-Manual to activate a station or group of stations with a specified runtime.
Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneous stations set in the program still applies. Manual Syringe Activation Directions Syringe activation example: Manually activate all the stations in Program 3 for 2 minutes each. Note: An irrigation program must be configured to activate Manual Syringe.
% (Percent) Adjust The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly, Percent Adjust allows you to tune your system easily without changing all the values in the program. % Adjust Directions 1. Press the % Adjust Key .
Page 25
Menu: Station Amps – Use this menu item to review each of the station’s last recorded voltage amperage, nominal amperage value, tolerance value, alarm events, pump nominal amperage value. Use the Input Dial to scroll through the available stations. Use the Down arrow to scroll down to the data fields.
PUMP COMMON AUTO PUMP COMMON Troubleshooting Guide Power Transformer Pump AC Power Terminals Station Common Output Board WARNING Board HIGH VOLTAGE 115V Electrical Protection 1 - Main Power Switch / 1.5A Circuit Breaker - Protects the controller from a short circuit on the incoming power line.
Page 27
Power Distribution Board PUMP COMMON AUTO PUMP COMMON Station Output Board PUMP COMMON DS4 DS5 AUTO PUMP COMMON 5V 9V 12V VP Timing Mechanism LED Indicators 10 - Pump Relay LED Indicator - When illuminated, the pump relay is activated. 11 - Common Relay LED Indicator - When illuminated, the common relay number 1 is activated.