94 => Initial
96 => Stop Scan
97 => Start running tour 1
98 => Frame scan (60 degree / step)
Default speed is 32. It can be changed by EVF Keyboard (Shift + A.Pan setting
speed.
Dwell time: default is 2 sec; It can be changed by EVF Keyboard Set + A.Pan
setting dwell time of A pos or B pos.
99 => Auto scan (360 degree)
Default speed is 32. It can be changed by EVF Keyboard (Shift + A.Pan setting
speed).
We can even set camera's ICR Day/Night function with RS-485 command via
keyboard. How to do this? Press Position + 88 to link to Day mode or Position + 89
to link to Night mode, "ICR AUTO" message will be shown on the right-bottom part
of the screen. If OSD Day/Night ICR mode is "AUTO", it cannot be controlled by
preset position setting.
Set the parameter of a preset position: Press Set + Position to set the parameter
of a preset position. You can set the going-to speed (1~239), dwell time (1~239
seconds), and the title of the position. Shift the joystick Right/Left to change bits,
and shift the Joystick Up/Down to change the alphanumeric characteristic. The
available alphanumeric characteristics are 0~9, A~Z, &, ?, !, :, ', ., ,, /, -, and a
space.
Delete a preset position: Press Clr + Position to delete a preset position. The
system will ask you to enter the position number that you would like to delete, and
then press Enter.
120