A. This section supplies functional test and troubleshooting procedures for RESCU 406AFN
Emergency Locator Transmitter ELT.
NOTE: Transmitter Unit P/N 1152682-2 is backward compatible to Transmitter Unit P/N 1152682-1,
and can be used with an AIM P/N 1152780-1.
B. Refer to REPAIR (page 601) for repair procedures. Data for special tools and test equipment are
included in Table 101 and in SPECIAL TOOLS, FIXTURES AND EQUIPMENT (page 901). An
illustrated parts list is included in the ILLUSTRATED PARTS LIST (page 1001).
C. Connector pin-outs for RESCU 406AFN are given in Tables 102 to 105.
D. Fault isolation flowcharts for RESCU 406AFN are given in Figures 103 to 105.
Nomenclature
406 MHz Digital Message Decoder BT100S/A/D
12/28 V dc Power Supply
Beacon Test Set
Portable Test Set
Spectrum Analyzer
Test System
Coaxial from TU to BT100AVS
Cable
12/28 V dc Power Supply Cables
2.
Installed System Test
The installed system tests are used to perform tests of the basic functions of the ELT system. These
tests do not give specified levels of performance for one or more of the functions of the ELT but they
do show that the system operates satisfactorily. If the results are unsatisfactory for a unit during one of
these tests, refer to the fault isolation flowcharts (Figures 103 to 105) to isolate the problem.
A. Self-test #1 (Started from Transmitter Unit)
NOTE: Consult with the responsible ATC/CAA/SAR for permission prior to performing self-test.
(1)
If the optional remote panel is installed, set the switch on the remote panel to ARMED.
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
1152682

TESTING AND FAULT ISOLATION

TABLE 101. TEST EQUIPMENT
(Equivalent substitutes may be used)
Model, Manufacturer
(WS Technologies)
E3632A (HP)
BT100AVS/AVtriple
(WS Technologies)
ARG5410
(Sartech Electronics)
HP8590 (Agilent)
TM
Rescu 406
50 ohm coaxial (V07217)
Generic (V07217)
Testing/Troubleshooting
Testing/Troubleshooting
Testing/Troubleshooting
Testing/Troubleshooting
Testing/Troubleshooting
Testing/Troubleshooting
Programming
Programming
23-24-02
Application
Page 101
Oct 27/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1152682-2

Table of Contents