Before rigging make sure that the installation area can hold a minimum point load of 10
times the projector's weight.
CAUTION: Fixture may cause severe injuries when crashing down. If you have
doubts concerning the safety of a possible installation, do not install the
fixture!
CAUTION: Use two appropriate clamps to rig the fixture on the truss. Follow
the instructions mentioned at the bottom of the base. Make sure that the
device is fixed properly! Ensure that the structure (truss) to which you are
attaching the fixtures is secure.
DANGER OF FIRE! When installing the device, make sure there is no highly
inflammable material (decoration articles, etc.) within a distance of minimum
0.5m.
For overhead use, always install a safety rope that can hold at least 10 times the weight
of the fixture.

6.2. Mains Connections

Connect the device to mains with the power-plug. Wire correspondence is as follow:
WIRE
Brown
Blue
Yellow/Green
The earth must to be connected! Pay attention to safety!
Before taking into operation for the first time, the installation has to be approved by an
expert.

6.3. DMX-512 Connection

Wires must not come into contact with each
other; otherwise the fixtures will not work at all,
or will not work properly. Only use a DMX cable,
3-pin XLR plugs and connectors in order to con-
trol with the fixture or one fixture with another.
If you are using the recommended controllers,
you can connect the DMX output of the controller directly with the DMX input of the
first fixture in the DMX chain. If you wish to connect DMX controllers with other XLR
output, you need to use adapter-cables.
PIN
INTERNATIONAL
Live
L
Neutral
N
Earth
ENGLISH
DMX use of XLR connectors
1 = Ground / Shield
2 = DMX +
3 = DMX -
INPUT
OUTPUT