Venting continued-
CONNECTION TO 2" (5.1 CM)
All of the venting connections must be leak checked with a soap and
water solution upon initial start-up of the water heater. Any leaks must
be repaired before continuing operation of the water heater.
THROUGH THE WALL VENTING: (HORIZONTAL VENTING):
Cut a 2 1/2 in (6.4 cm) diameter hole in the wall at the point where the vent
connector is going to pass through the wall. Use the proper cement to secure
the 90° vent terminal provided with the water heater to the vent connector. The
distance between the edges of the 90° vent terminal and the exterior wall (see
Figure 3) must be at least 1 in (2.5 cm). Use the proper cement and assembly
procedures to secure the vent connector joints between the terminal and the
blower outlet. Provide support brackets for every 5 ft (1.5 m) of horizontal vent.
2" VENT INSTALLATION
VENT PIPE
Figure 3
CONNECTION TO 3" (7.6 CM)
Figure 2
IMPORTANT
3" VENT INSTALLATION
14
VENT PIPE