Download Print this page

Century C-VFF30 Instructions Manual page 13

Lockoff/filterб repair kit

Advertisement

freely through the outlet. Use soap and/or a commercial leak detector solution
to inspect the gasket seals around the perimeter of the Lockoff for leaks. If leaks
are found, the Lockoff must be replaced. If no leaks are found, the Lockoff can be
reinstalled and returned to service.
Page 13 of 14
37. Tighten screws alternatively
from side to side across cover until
all are solidly fastened. Torque to
30 +/-3 in-lbs.
38.
Pressurize
opening with approximately 100
psi of air pressure. Draw a soap
bubble across the Lockoff outlet
and vacuum port (labeled "VAC") to
verify that no air is flowing through
either opening. If air escapes, the
rebuild has failed and the Lockoff
must be replaced. Apply a small
amount of vacuum to the port
labeled "VAC" to verify the air flows
C-VFF30 Repair Kit Instructions (Form 103-2)