Service

WARNING!
SERVICING THE SANTA FE COMPACT2, WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE
CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR
PROPERTY DAMAGE. ONLY QUALIFIED SERVICE PEOPLE SHOULD SERVICE THIS UNIT.

Replacement Parts

4025560
On/Off Switch
1970010
25A Relay
4027163
15A Relay
4029568
Compressor Overload
4021495
Control Knob
4025577
Clear Hose
4026221
Leveling Foot
4029567
Compressor
4027172
Humidity Control
4033032-03
Run Capacitor
4025569
Hose Adaptor
4035235-03
Fan Capacitor
4033358-08
Coil Set
4034477
Impeller
4036967
Defrost Thermostat

Refrigerant Charging

If the refrigerant charge is lost due to service or a leak,
a new charge must be accurately weighed in. If any of
the old charge is left in the system, it must be recovered
before weighing in the new charge. Refer to the
unit nameplate for the correct charge weight and
refrigerant type.

Compressor/Capacitor Replacement

This compressor is equipped with a two terminal
external overload and a run capacitor, but no start
capacitor or relay.
1-800-533-7533 | www.Santa-Fe-Products.com

Troubleshooting

CAUTION!
TROUBLESHOOTING SHOULD BE PERFORMED BY
A QUALIFIED HVAC TECHNICIAN.
Symptom
Neither fan nor
compressor
running.
Dehumidification
is being called for.
Compressor is
not running.
Dehumidification
is being called for.
Fan is running.
Compressor
cycles on and off.
Dehumidification is
being called for.
Santa Fe Compact2 Installation & Operation Instructions
Possible Reason
1. Dehumidifier unplugged
or no power to outlet.
2. Humidity control set
too high.
3. Loose connection in
internal or control wiring.
4. Defective compressor
relay.
1. Defective compressor
run capacitor.
2. Loose connection in
compressor circuit.
3. Defective compressor
overload.
4. Defective compressor.
5. Defrost thermostat open.
1. Low ambient
temperature and/or
humidity causing unit
to cycle through
defrost mode.
2. Defective compressor
overload.
3. Defective compressor.
4. Defrost thermostat
defective.
5. Dirty air filter(s) or air
flow restricted.
6. Defective fan or relay.
13