Siemens WM6HXE0LDN User Manual And Assembly Instructions page 64

Table of Contents

Advertisement

en Troubleshooting
Fault
The door cannot be opened. The temperature is too high.
The water is not draining.
Water is not flowing in. De-
tergent is not being dis-
pensed.
64
Cause
Water level is too high.
Power failure.
Drain pipe or water outlet
hose is blocked.
Drain pipe or water drain
hose is caught or jammed.
Drain pump is blocked.
Rinse Hold
is activated.
The water outlet hose is con-
nected too high.
Pump cover is not correctly
assembled.
Pump cover is not correctly
assembled.
You have not pressed 
The filter in the water inflow
is blocked.
The tap is turned off.
The water inlet hose is
kinked or jammed.
troubleshooting
Wait until the temperature has
dropped.
→ "Cancelling the programme",
Page 45
Start the Drain programme.
Open the door using the emergency
release.
→ "Emergency release", Page 70
Clean the drain pipe and the water
outlet hose.
Ensure that the drain pipe and wa-
ter drain hose are not kinked or
trapped.
→ "Cleaning the drain pump",
Page 56
Continue the programme by select-
ing Spin or Drain and pressing
.
→ "Resuming the programme when
the programme status is Rinse
Hold", Page 45
Install the water outlet hose at a
maximum height of 1 metre.
→ "Technical specifications",
Page 75
Correctly assemble the pump
cover.
Correctly assemble the pump
cover.
.
Press
.
"Clean the water inflow filter"
→ Page 59.
Turn on the tap.
Ensure that the water inlet hose is
not kinked or jammed.

Advertisement

Table of Contents
loading

Table of Contents