Be aware that the body of the Be aware that the body of the Siemens Microinverter is the heat sink and can reach a Microinverter is the heat sink and can reach a temperature of 80° C (176 C (176°...
Page 5
The Siemens Microinverter System The Siemens Microinverter System is the world’s most technologically advanced inverter system for use in utility-interactive applications. This manual details the safe installation and operation of the Siemens Microinverter. The three key elements of a Siemens Microinverter System are: the Siemens Microinverter •...
Ease of Design PV systems using Siemens Microinverters are very simple to design and install. You will not need string calculations, and you can install individual PV modules in any combination of module quantity, type, age and orientation. You won’t need to install cumbersome centralized or string inverters.
Siemens Microinverter Installation Follow the instructions in this section to install Siemens SMIINV215R60XX Microinverters. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Be aware that installation of this equipment includes risk of electric shock. Normally grounded conductors may be ungrounded and energized when a ground fault is indicated.
As the Siemens Limited Warranty does not cover “acts of God” such as lightning strikes, and As the Siemens Limited Warranty does not cover “acts of God” such as lightning strikes, and As the Siemens Limited Warranty does not cover “acts of God”...
Installation Procedure Installation Procedure Installing the Siemens Microinverter System involves several key steps. Each step listed below is Microinverter System involves several key steps. Each step listed below is Microinverter System involves several key steps. Each step listed below is detailed in the following pages.
NEC required by the NEC and local jurisdictions. National Electrical Code is Registered Trademark of the National Fire Protection Association is Registered Trademark of the National Fire Protection Association Page 10 Copyri Copyright 2011 Siemens Industry, Inc. 141-00015, Rev 01...
The connector cable spacing is designed for the widest PV modules compatible with the widest PV modules compatible with Siemens Microinverters. If narrower modules Microinverters. If narrower modules are used, it may be necessary to account for excess cable by adding a are used, it may be necessary to account for excess cable by adding a are used, it may be necessary to account for excess cable by adding a ‘loop’...
Use one or two additional clips, tie wraps, or other Use one or two additional clips, tie wraps, or other support scheme to secure the support scheme to secure the cable between connectors. cable between connectors. Page 13 Copyri Copyright 2011 Siemens Industry, Inc. 141-00015, Rev 01...
Page 14
NOTE: If you need to remove an IP67 sealing cap. : If you need to remove an IP67 sealing cap. You must use the Siemens Siemens disconnect tool or a #3 Phillips screwdriver. screwdriver. Sealing caps may not be reused.
Ensure that the gland portion is rotating, not the cap. g. Hold the cap with an Siemens disconnect tool, or insert a #2 Phillips screwdriver. Hold the gland portion with a 24 mm (7/8”) wrench. Tighten the gland portion until the ratcheting feature on the cap bottoms out.
Conductor (GEC) for system ground is also required as described in the next step. for system ground is also required as described in the next step. for system ground is also required as described in the next step. Page 16 Copyri Copyright 2011 Siemens Industry, Inc. 141-00015, Rev 01...
B grounding washers to ground the microinverter chassis as described in step 4, follow the step below. Each in step 4, follow the step below. Each Siemens Microinverter comes with a ground clip that can Microinverter comes with a ground clip that can accommodate a 6-8 AWG conductor.
Step 10 – Complete the Complete the Installation Map The Siemens Installation Map is a diagrammatic representation of the physical location of each Installation Map is a diagrammatic representation of the physical location of each Installation Map is a diagrammatic representation of the physical location of each microinverter in your PV installation.
When the system is energized and all microinverters are detected by the Envoy Communications Gateway, you can create the virtual array in Enlighten from the Gateway, you can create the virtual array in Enlighten from the Siemens map you created. Once map you created. Once the virtual array is built, Enlighten displays a graphic representation of the PV system.
Operating Instructions ting Instructions The Siemens Microinverter is powered on when sufficient DC voltage from the module is applied. Microinverter is powered on when sufficient DC voltage from the module is applied. Microinverter is powered on when sufficient DC voltage from the module is applied.
PV system does not operate correctly. WARNING: Do not attempt to repair the Siemens Microinverter; it contains no user- serviceable parts. If it fails, please contact Siemens customer service to obtain an RMA number and start the replacement process.
2. Verify that AC line voltage at the service entrance conductors and at the junction box for each Siemens branch are within the ranges are shown in the following table: 120/240 VAC or 208Y/120 VAC Single Phase 208Y/120 VAC Three Phase...
1. Disconnect the AC by opening the branch circuit breaker. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Disconnect the Siemens Microinverter from the electrical utility grid prior to servicing. 2. Disconnect the first AC connector in the branch circuit.
9. Use Enlighten’s Array Builder function to add the newly detected microinverter to the s Array Builder function to add the newly detected microinverter to the s Array Builder function to add the newly detected microinverter to the virtual array. Page 24 Copyri Copyright 2011 Siemens Industry, Inc. 141-00015, Rev 01...
Technical Data Technical Considerations The Siemens SMIINV215R60XX Microinverters are designed to operate with most 60-cell PV modules. Be sure to verify the voltage and current specifications of your PV module match those of the microinverter. For more information, refer to the Siemens website (http://www.usa.siemens.com/microsolar) for a list of compatible PV module racking systems and...
Technical Specifications Siemens SMIINV215R60XX Microinverter Operating Parameters Topic Unit Typical DC Operating Parameters MPPT voltage range Operating Range Maximum DC input voltage Minimum / Maximum start voltage Maximum DC input short circuit current Maximum DC input current 10.5 Ground fault protection...
Page 27
Siemens SMIINV215R60XX Microinverter Operating Parameters Topic Unit Typical Miscellaneous Operating Parameters Inverters per 20 amp AC branch circuit 240 Vac or 208 Vac Single Phase 208 Vac Three phase Peak inverter efficiency 96.3 CEC weighted efficiency 96.0 Static MPP tracking efficiency (weighted EN 50530) 99.6...
Microinverter remains installed at the originally-installed end user location. During the Warranty Period, Siemens will, at its option, repair or replace the Defective Product free of charge, provided that Siemens through inspection establishes the existence of a defect that is covered by the Limited Warranty.
Page 29
The Limited Warranty does not apply to, and Siemens will not be responsible for, any defect in or damage to any Siemens Microinverter: (1) that has been misused, neglected, tampered with, altered, or otherwise damaged, either internally or externally;...
Page 34
Siemens Industry, Inc. Infrastructure & Cities Sector Low and Medium Voltage 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 www.usa.siemens.com/microsolar info.us@siemens.com...