(4) Identification of parts to be removed, unhooked,
unlocked, released, unplugged, unclamped, or
desoldered.
P = Spring, L = Locking Tab, S = Screw,
H = Hex Screw, CN = Connector
e.g. 2(S-2) = two Screws of (S-2),
2(L-2) = two Locking Tabs of (L-2)
(5) Refer to the following "Reference Notes in the
Table."
Important precautions concerning the
LCD Panel Assembly:
1. When you disassemble/re-assemble the LCD
Panel Assembly.
• Do not pull the FFC Cable and Board Cable
forcefully when you re-assemble.
• Be careful not to scratch the display panel when
assembling.
• Make sure to replace the Decoration Plate to a new
one when replacing the LCD Panel Assembly.
• Make sure the T-CON Module and T-CON Holder
are securely in place when re-assembling.
2. When you disassemble/re-assemble the
Function CBA or the IR Sensor CBA Unit.
• Be careful not to scratch the display panel when
assembling.
• The Function CBA Unit, Function Knob, Switch
Shield and Knob Frame are fixed in place by the
hooks. Make sure these hooks are not damaged.
Make sure the Function CBA Unit, Function Knob
and Knob Frame.
• Make sure the tact switches operate normally after
replacing the Function CBA.
• Make sure the Sensor Shield, Sensor Lens and IR
Sensor CBA Unit are securely in place when re-
assembling.
3. When you disassemble/re-assemble the Front
Cabinet.
• Be careful not to break the hook. If you pull with too
much force, the hooks may be damaged.
• Make sure to replace the Cell Cushion, Gasket,
Grand Tape and Decoraion Plate to a new one when
replacing the Front Cabinet.