HeatMax II Furnace Installation and Operation Manual

12 General information on HeatMax II (DF01001)

12.1 Appliance performance

Fuel type
Recommended heating area
Firebox volume
Maximum burn time
[*]
Maximum input capacity (dry cordwood)
Overall heat output rate (min. to max.)
Nominal heat output
at 15lb/ft³ fuel loading density
Average overall efficiency
Delivered heat output rate (min. to max.)
Average delivered efficiency
Optimum efficiency
(9)
Average particulate emissions rate
Average CO
(12)
Average electrical power consumption
Recommended heating area and maximum burn time may vary subject to location in home, chimney
[*]
draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given
appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature
considering that the space configuration and the presence of heat distribution systems have a significant
impact in making heat circulation optimum.
Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume,
(1)
maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the
standard at 10 lb/ft³ and with a moisture content between 18% and 28%.
Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb.
(2)
Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle.
(3)
Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat
(4)
demand.
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one
(7)
total burn cycle.
Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate
(8)
thermostat demand.
Optimum overall efficiency at a specific burn rate (LHV).
(9)
Based on delivered heat output.
(10)
This appliance is officially tested and certified by an independent agency.
(11)
Carbon Monoxyde. Based on overall heat output at 10lb/ft³ fuel loading density.
(12)
Unless
stated otherwise, measures were taken directly at the main power source and include all
(13)
electrical components present in the appliance.
72
(1)
[*]
(2)
(3)
(4)
(7)
(8)
(10)(11)
(13)
Dry cordwood
1,000 to 2,500 ft² (93 à 232 m²)
3.6 ft³ (0.102 m³)
10 h
310,000 BTU
15,436 BTU/h to 49,638 BTU/h (4.5 kW to 14.5 kW)
75,000 BTU/h
76.7 % (HHV)
(5)
12,635 BTU/h to 44,857 BTU/h (3.7 kW to 13.1 kW)
62.7 % (HHV)
(5)
84.9%
0.654 lb/mmBTU (0.282 g/MJ)
11.22 lb/mmBTU (4.81 g/MJ)
250 W
82.9 % (LHV)
(6)
68.3 % (LHV)
(6)