Cooling
<Capacity>
150%
Indoor : 27/19 C
140%
130%
120%
110%
100%
90%
80%
70%
60%
-10
<Input>
120%
Indoor : 27/19 C
110%
100%
90%
80%
70%
60%
50%
40%
30%
20%
-10
*Both capacity and input decrease when temperature is 19 or less degrees C, for compressor
frequency restrictions operate.
*Both capacity and input decrease when temperature is 40 or more degrees C, as compressor speed is
decreased due to current release protection.
*Both capacity and input change largely when temperature is 10 or less degrees C, as outdoor fan speed
is decreased due to low ambient temperature cooling control.
*Both capacity and input change more largely at less than 0 degrees C of ambient temperature as
outdoor fan speed is decreased further.