TROUBLESHOOTING GUIDE
Unit leaks water
Possible Cause
Unit is not level
Drain line clogged or kinked
Drain is clogged, preventing water from escaping
Drain line does not have a downward slope
Unit runs but does not cool
Possible Cause
Compressor not running
System undersized
Compressor is overheating
Evaporator fan runs but compressor does not
Possible Cause
Compressor and/or starting components faulty
Compressor is overheating
Compressor runs but evaporator fan does not
Possible Cause
Faulty fan motor
Faulty fan relay
Compressor short-cycles
Possible Cause
Evaporator fans blow on bottle probe
Unit low on refrigerant charge
Condensing fan motor/capacitor faulty
Compressor and/or starting components faulty
Humidity in cellar too high
Possible Cause
Page 1 | 1-800-343-9463
Solution
Unit should be level in wall to prevent leaking
Disconnect drain and clear it out
Fix drain line so there is a downward slope from the unit to the drain
Melt ice with blow drier. Soak up with a towel.
Solution
Make sure both fans are running and coils are not dirty or blocked by
foreign objects.
Contact Customer Service at 1-800-343-9463
Contact Customer Service at 1-800-343-9463
clean condenser coil as possible cause of compressor overheating. If
problem repeats, contact Customer Service at 1-800-343-9463.
Solution
Contact Customer Service at 1-800-343-9463
clean condenser coil as possible cause of compressor overheating. If
problem repeats, contact Customer Service at 1-800-343-9463.
Solution
Contact Customer Service at 1-800-343-9463
Contact Customer Service at 1-800-343-9463
Solution
Move bottle probe to a more central location
Call Customer Service at 1-800-343-9463
Call Customer Service at 1-800-343-9463
Call Customer Service at 1-800-343-9463
Solution
Install proper vapor barrier