Remove The Dc Sensor - Kohler K-10668 Homeowner's Manual

Exposed flush valve
Table of Contents

Advertisement

Available languages

Available languages

Cap
DC Sensor
Connector
Screw

Remove the DC Sensor

Close the control stop valve (refer to the "Control Stop Valve
Operation" section).
Using a 3/32" hex head wrench, remove the setscrew from the
valve cap.
Remove the cap by carefully lifting from the valve body.
Disconnect the DC sensor connector to the solenoid by grasping
each side of the connector pair and pulling apart. Do not separate
the connector pair by pulling on the wires.
Position the cap on its side and look inside.
Remove the battery.
Remove the screws that hold the DC sensor in place inside the
cap.
Turn the cap over and slide the DC sensor, sensor strap, and
screws into your hand.
NOTE: The battery inside the sensor may be considered hazardous
waste. Discard the old DC sensor and/or battery in accordance with
any applicable codes.
If replacing the DC sensor, discard the old DC sensor and battery.
Kohler Co.
Setscrew
DC Sensor
Sensor Strap
7
1140767-5-A

Advertisement

Table of Contents
loading