Advertisement

FACTORY ID: 500
HK070F
HK175FW
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR
THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION,
ALTERATION OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within
the area in which it is used. Failure to provide adequate combustion and ventilation air will result in
asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 7.
This appliance shall be installed in accordance with the rules in force,
WARNING
and used only in sufficiently ventilated space. Consult instructions before
installation and use of this appliance.
Model Numbers
HK045F / HK070F / HK125FW /
HK175FW / HK215FW
© 2020 BAR Group Pty Ltd
Head Office
15 Hudson Place
Mulgrave NSW 2756, Sydney
User's Manual &
Operating Instructions
HK125FW
HK215FW
BPKI-400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HK045F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BE HK045F

  • Page 1 DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily injury, or loss of life.
  • Page 2: Table Of Contents

    THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience or and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3: Safety Information

    This appliance If the supply cord is damaged, it must be is rated at 98% combustion efficiency, but does replaced by a special cord or assemble available from the manufacturer, its service agent or produce small amounts of carbon monoxide.
  • Page 4 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz Phase Single Single Single Single Single Specifications subject to change without notice. Features Models: HK045F / HK070F Upper Shell Hot Air Outlet Extension Handle Cord Wrap Lower Shell Fan Guard Side Cover...
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Models: HK045F / HK070F Note: Save the box and packaging materials - Remove the heater and all packaging materials from the shipping carton for future storage.
  • Page 6 - Phillips Head Screw Driver - 8 mm open end wrench Tip: Be sure to remove the axle from the - 19 mm open end wrench side of the Styrofoam packaging. Tip: Use a power screwdriver and locking wrench for easier assembly.
  • Page 7 7 NOTE: DO NOT do this if there is fuel in the tank. 9. Remove the wheels to secure the second set of Figure 7 screws through the rear handle. © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 8: Operation

    EXPLOSION. operate safely at a minimum - NEVER store paraffin in the living space. Paraffin ambient temperature of -20° C. should be stored in a well ventilated area outside Use caution when servicing in the living area. WARNING wet areas. Disconnect power...
  • Page 9 NOTE: If if the heater still does not ignite, refer to “Troubleshooting Guide” on page 12. “Troubleshooting Guide” on page 12. NOTE: The HK045F and HK070F do not have a room temperature display feature. The room temperature display will indicate the TIP: If the heater does not ignite;...
  • Page 10: Maintenance

    3. Using a small amount of paraffin, rinse and AIR FILTERS: swirl the paraffin inside of the fuel tank, empty The air intake filter should be replaced or washed the tank fully. with soap and water and dried thoroughly every 500 4.
  • Page 11 Remove all accumulated dust and dirt with a terminals to 0.140” (3.5mm) See Figure 16. damp cloth, taking care not to bend any of the fan blades. Be sure the blades are dry before Spark Plug re-starting the heater. For fan assembly removal Burner Head see Figure 14.
  • Page 12: Wiring Diagram

    Correct pump pressure is as make this necessary immediately. To clean dirt follows: from nozzle, blow compressed air through nozzle front. It may be necessary to soak the nozzle in Model Number Pump Pressure paraffin to loosen any dirt particles.
  • Page 13: Troubleshooting Guide

    4. Improper electrical connection supply. between temperature limit sensor 3. Check / replace the fuse. and circuit board. 4. Inspect all electrical connections (see wiring diagrams on page 11). © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 14: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 34** 35** 41** 38** 37** *HK045F / HK070F Only 39** **HK125FW / HK175FW / HK215FW Only © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 15: Parts List

    70-001-0103 01.02.70.004510015 70-001-0103 01.02.70.004510015 Front Handle Rear Handle Wheel Support Frame Wheel Axle Wheel Wheel Nut Hardware Kit (not pictured) 70-056-0100 70-056-0100 70-056-0100 70-056-0100 Cord Wrap Motor Supporter 70-020-0600 01.01.70.004510703 © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 16 Hardware Kit (not pictured) 70-056-0210 70-056-0210 70-056-0210 70-056-0210 Cord Wrap 70-032-0200 01.02.70.012510028 70-032-0200 01.02.70.012510028 Motor Supporter 70-020-0610 01.01.70.012510710 70-020-0610 01.01.70.012510710 Motor End Pump Gasket 01.01.70.021510097 Pump End Gasket 01.01.70.021510098 01.01.70.021510098 © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 17 Wheel 70-041-0150 01.03.90.003610031 Wheel Nut 70-041-0550 01.01.70.012510054 Hardware Kit (not pictured) 70-056-0210 70-056-0210 Cord Wrap 70-032-0200 01.02.70.012510028 Motor Supporter 70-020-0610 01.01.70.012510710 Motor End Pump Gasket 01.01.70.021510097 Pump End Gasket 01.01.70.021510098 © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...
  • Page 18 ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ © 2020, BE Pressure Kerosene Forced Air Heater User’s Manual...

This manual is also suitable for:

Hk070fHk125fwHk175fwHk215fw

Table of Contents