ADJUSTABLE FEATURES
TRANSISTOR PUMP CONTROLS
switch input signal is received by the control card. SL3
limit switch is a normally open switch connected to battery
negative, the switch closing enables speed limit.
Range
0% to 100% battery volts
Setting
0 to 255
Resolution
0.375 volts per set unit
Example: Setting of 50=18.75 volts
FUNCTION 52:
MODE 2 - CONTROLLED ACCELERATION
(Push CONT 5)
Same as function 48.
FUNCTION 53:
MODE 2 - SPEED LIMIT 2 (SL2)
(Push CONT 6)
Same as Function 49.
FUNCTION 54:
MODE 2 - SPEED LIMIT 3 (SL3)
(Push CONT 7)
Same as Function 50.
FUNCTION 55:
NOT APPLICABLE
This function is not applicable to this type of control and
should not be adjusted.
FUNCTION 56:
MODE 3 - CONTROLLED ACCELERATION
(Push CONT 9)
Same as function 48.
FUNCTION 57:
MODE 3 - SPEED LIMIT 2 (SL2)
(Push CONT 10)
Same as Function 49.
FUNCTION 58:
MODE 3 - SPEED LIMIT 3 (SL3)
(Push CONT 11)
Same as Function 50.
FUNCTION 59:
NOT APPLICABLE
This function is not applicable to this type of control and
should not be adjusted.
FUNCTION 60:
MODE 4 - CONTROLLED ACCELERATION
(Push CONT 13)
Same as function 48.
FUNCTION 61:
MODE 4 - SPEED LIMIT 2 (SL2)
(Push CONT 14)
Same as Function 49.
FUNCTION 62:
MODE 4 - SPEED LIMIT 3 (SL3)
(Push CONT 15)
Same as Function 50.