Johnson Controls CD-W00-0-2 Series Installation Manual

Johnson Controls CD-W00-0-2 Series Installation Manual

Wall mount co2 and temperature transmitters

Advertisement

Quick Links

North American emissions
compliance
United States
This equipment has been tested and found to comply with
the limits for a Class A digital device pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
this equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area may cause harmful
interference, in which case the users will be required to
correct the interference at their own expense.
Warning (Part 15.21)
Changes or modifications not expressly approved by the
party responsible for compliance could void the user's
authority to operate the equipment.
Canada
This Class (A) digital apparatus meets all the requirements
of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la Classe (A) respecte toutes
les exigences du Règlement sur le matériel brouilleur du
Canada.
Industry Canada Statement(s)
This device complies with Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two
conditions:
1.
This device may not cause interference, and
2.
This device must accept any interference, including
interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions
suivantes :
1.
L'appareil ne doit pas produire de brouillage, et
2.
L'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le
fonctionnement.
CD-W00-x0-2 Series Wall Mount CO
Temperature Transmitters Installation Guide
Installation
Important: The CD-W00-x0-2 Series Wall Mount
CO
and Temperature Transmitters are intended
2
to provide an input to equipment under normal
operating conditions. Where failure or malfunction
of the transmitter could lead to personal injury or
property damage to the controlled equipment or
other property, additional precautions must be
designed into the control system. Incorporate and
maintain other devices, such as supervisory or alarm
systems or safety or limit controls, intended to warn
of or protect against failure or malfunction of the
transmitter.
Important: Le CD-W00-x0-2 Series Wall Mount
CO
and Temperature Transmitters est destiné
2
à transmettre des données entrantes à un
équipement dans des conditions normales de
fonctionnement. Lorsqu'une défaillance ou un
dysfonctionnement du CD-W00-x0-2 Series Wall
Mount CO
Transmitters risque de provoquer des
2
blessures ou d'endommager l'équipement contrôlé
ou un autre équipement, la conception du système
de contrôle doit intégrer des dispositifs de protection
supplémentaires. Veiller dans ce cas à intégrer de
façon permanente d'autres dispositifs, tels que
des systèmes de supervision ou d'alarme, ou des
dispositifs de sécurité ou de limitation, ayant une
fonction d'avertissement ou de protection en cas
de défaillance ou de dysfonctionnement du CD-
W00-x0-2 Series Wall Mount CO
Transmitters.
Risk of Electric Shock.
Disconnect the power supply before making electrical
connections to avoid electric shock.
Risque de décharge électrique.
Débrancher l'alimentation avant de réaliser tout
raccordement électrique afin d'éviter tout risque de
décharge électrique.
Part No. 24-10864-11 Rev. B
and Temperature
2
 CAUTION
 CAUTION
*241086411B*
CD-W00-00-2, CD-W00-N0-2
and
2
2021-04-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CD-W00-0-2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Johnson Controls CD-W00-0-2 Series

  • Page 1 CD-W00-x0-2 Series Wall Mount CO Temperature Transmitters Installation Guide Part No. 24-10864-11 Rev. B 2021-04-02 North American emissions Installation compliance Important: The CD-W00-x0-2 Series Wall Mount and Temperature Transmitters are intended United States to provide an input to equipment under normal operating conditions.
  • Page 2 Important: When using multi-stranded wire cable, apply a cable ferrule to the cable end. If the distance  CAUTION between the sensor and the controller is over 3 meters (9.8 feet), use shielded cable. Connect the shield at the controller end of the cable. Risk of Property Damage.
  • Page 3 Secure the mounting base to the wall, using at least Figure 4: Screw terminals two field-supplied screws. See Figure 3. Figure 3: Route the cable from behind and mount the wall plate Note: When you bring the cable through the wall, seal the cable opening.
  • Page 4: Setup And Adjustments

    (AI) high range to compensate specifications, replace the units. For a replacement for sensor placement at other than the standard transmitter, contact the nearest Johnson Controls® calibration altitude. representative. To do this, reset the 2,000 ppm value using the controller’s compensation factor (CF) shown in Figure 7 or Figure 8.
  • Page 5: Technical Specifications

    UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, FCC Compliant to CFR 47, Part 15, Subpart B, Class A Europe CE Mark - Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC directive.
  • Page 6 Global Safety Information • Dieser Sensor / Transmitter kann nur wandmontiert eingesetzt werden. English • Der elektrische Anschluß ist nach den örtlichen Vorschriften durch autorisiertes Personal • Make sure that the line power supply is in accordance durchzuführen. with the power supply specified in the Technical •...
  • Page 7 • La conexión eléctrica deberá ser realizada según las • Försörjningsspänning och lågspänning ska tillföras disposiciones locales y por personal autorizado. åtskilt • La tensión de alimentación y la baja tensión deben • Vid användning av flexibla ledningar ska kabelskor tenderse por separado.
  • Page 8 • Dotknięcie elementów będących pod niebezpiecznym • Curto-circuito ou fios mal conectados podem provocar napięciem może spowodować porażenie i poważne danos permanentes no equipamento. obrażenia lub nawet śmierć. • Não aderir a estas instruções operacionais pode • Zwarcia lub nieprawidłowo podłączone kable mogą provocar ferimentos ou danos ao equipamento spowodować...
  • Page 9: Product Warranty

    Your use of this product constitutes an agreement to such terms. Patents Patents: https://jcipat.com Contact information Contact your local branch office: www.johnsoncontrols.com/locations Contact Johnson Controls: www.johnsoncontrols.com/contact-us Single point of contact APAC Europe NA/SA JOHNSON CONTROLS JOHNSON CONTROLS...
  • Page 10 © 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice.

This manual is also suitable for:

Cd-w00-00-2Cd-w00-n0-2

Table of Contents