4.4

Minimum clearances

B
A
B
C
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.5

Using the installation template

Use the installation template to ascertain the locations at
which you need to drill holes and make perforations.
4.6

Setting the variable profile frame

Note
The product is equipped with a variable profile
frame. This allows you to replicate the exact width
of the old unit when carrying out replacement in-
stallations. The variable profile frame offers the
option to adjust the installation width to the wall
within the range of 440 to 460 mm.
0020214272_04 atmoTEC exclusive, atmoTEC plus Installation and maintenance instructions
A
B
C
Minimum clearance
450 mm
10 mm
250 mm
1.
Undo three screws on each frame.
2.
Slide the profile frame into the required position.
3.
Use the screws to secure the frame.
4.7

Wall-mounting the product

1.
Check the load-bearing capacity of the wall.
2.
Note the total weight of the product.
3.
Only use fixing material that is permitted for the wall.
Conditions: The load-bearing capacity of the wall is sufficient, The fixing
material may be used for the wall
Wall-mount the product as described.