Components; Control Panel Components - Westinghouse WGen5300 User Manual

Hide thumbs Also See for WGen5300:
Table of Contents

Advertisement

Available languages

Available languages

COMPONENTS

COMPONENTS

CONTROL PANEL COMPONENTS

1. Fuel Selector Switch: Used to select gas or propane
operation.
2. Push Button START/STOP Switch: Push to once to
automatically start the engine. Push again to stop the
engine.
3. Battery Switch: Turns battery ON and OFF. Must be
ON before electric or remote start.
4. Voltage Selector Switch: Select 120 Volts or 240
Volts. Shut the generator OFF before switching
voltages.
5. 120/240 Volt AC, 30 Amp NEMA 14-30R Twist-Lock
Receptacle: Receptacle can supply a maximum of
30 Amps.
6. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
7. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
10 | Westinghouse Outdoor Power Equipment, LLC
8. 20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacles to 20 Amps..
9. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the TT-
30R receptacle to 30 Amps.
10. 22-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through
each 120 Volt leg on L14-30R to 22 Amps.
11. Ground Terminal: The ground terminal is used to
externally ground the generator.
12. Smart Switch Outlet: Connects the Westinghouse
ST Switch (sold separately) to the control panel.
13. Battery Indicator: Indicates that power is ON. Light
will remain illuminated while the unit is ON.
14. Battery Charging Port: Used to charge the battery
with the included battery charger.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgen3600dfcvWgen5300df

Table of Contents