Fanmaster HDR40 Instruction Manual

Fanmaster HDR40 Instruction Manual

Industrial diesel radiant heater

Advertisement

Quick Links

FA NM A ST E R
cooling heating ventilation extraction
INSTRUCTION MANUAL
INDUSTRIAL DIESEL RADIANT HEATER
MODEL: HDR40
FOR INDUSTRIAL USE ONLY
ADEQUATE VENTILATION REQUIRED
TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS &
INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS

Advertisement

Table of Contents
loading

Summary of Contents for Fanmaster HDR40

  • Page 1 FA NM A ST E R cooling heating ventilation extraction INSTRUCTION MANUAL INDUSTRIAL DIESEL RADIANT HEATER MODEL: HDR40 FOR INDUSTRIAL USE ONLY ADEQUATE VENTILATION REQUIRED TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS & INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS...
  • Page 2: For Your Information

    FOR YOUR INFORMATION Thank you for purchasing a Fanmaster diesel heater. Please read this instruction manual carefully before using this heater. Disclaimer: Fanmaster reserves the right to make alterations to specifications, quantities, dimensions, for production or other reasons, subsequent to publication.
  • Page 3 ALWAYS CHECK THE POWER CABLE BEFORE USING THE APPLIANCE. IT MUST NOT BE BENT, TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED. • IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A SERVICE AGENT OR A QUALIFIED PERSONS. •...
  • Page 4: Product Description And Specifications

    2. PRODUCT DESCRIPTION & SPECIFICATIONS PRODUCT DESCRIPTION Industrial diesel or kerosene portable radiant heater with open combustion chamber. SPECIFICATIONS MODEL HDR40 40KW Heat Output* 136,480 BTU Air Flow (L/s) Fuel Type Diesel or Kerosene Fuel Consumption (L/h) Fuel Nozzle Size (gph)
  • Page 5: Assembling Instructions

    3. ASSEMBLING INSTRUCTIONS Remove the heater from the carton. If the heater is damaged, please contact Fanmaster or where you purchased the heater from. 1. Attached Radiant Visor to the top/rear of the Radiant Cone Assembly using 3 screws 2. Attach Safety Guard to front of heater with screws provided...
  • Page 6 4. OPERATING INSTRUCTIONS • Position the heater on a flat, level, non-flammable & solid surface. • Only position the heater in the normal upright position (on the wheels) • Do not place the heater near walls, corners or low ceilings. •...
  • Page 7: Cleaning, Maintenance And Storage

    5. CLEANING, MAINTENANCE & STORAGE • Before starting any maintenance task, shut down, unplug and let the heater cool down for at least 15 minutes. • Do not attempt any electrical repair yourself. If the heater needs service or repair, contact a qualified persons.
  • Page 8 5. CLEANING, MAINTENANCE & STORAGE - CON Fuel Nozzle • Nozzles should be cleaned or replaced at least once per heating season. • To clean dirt from nozzle, blow compressed air through nozzle. It may be necessary to soak nozzle in clean diesel to help loosen any particles. MAINTENANCE SCHEDULE PART FREQUENCY...
  • Page 9: Wiring Diagram

    6. WIRING DIAGRAM...
  • Page 10: Parts Breakdown

    7. PARTS BREAKDOWN...
  • Page 11: Troubleshooting

    Fuel Filter is dirty or blocked Clean fuel filter with clean fuel Ignition error Contact Fanmaster Damaged cable Replace or contact Fanmaster Sensor is damaged Replace or contact Fanmaster Turn the heater off & wait until Internals overheating the heater has cooled down...
  • Page 12 8. TROUBLESHOOTING - CONTINUED PROBLEM CAUSE SOLUTION The switch is in the “O” OFF Turn the switch to “I” ON postion Check the plug is properly connected to the power No power source. Check the power Heater does not supply Adjust the thermostat higher Thermostat setting than the ambient temperature...
  • Page 13: Warranty

    To make a claim under the warranty, take the product (with proof of purchase) to the store where you purchased the product or go to https://www.fanmaster.com.au/warranty-claims-returns. This warranty is given by Fanmaster Pty Ltd ABN: 45 353 934 457 Unit 1/6-8 Yalgar Rd, KIRRAWEE NSW 2232 P: 1300 900 345 E: warranties@fanmaster.com.au...
  • Page 16 FA NM A ST E R cooling heating ventilation extraction Fanmaster Pty Ltd | 1/6-8 Yalgar Road, KIRRAWEE NSW 2232 1300 900 345 | sales@fanmaster.com.au | www.fanmaster.com.au N11664 MADE IN CHINA...