4. Installation Instructions

How to Install Your Alarm
Direct Plug Alarm
To install:
1. Remove the switch cover.
2. Choose a standard 120 V unswitched outlet
to plug the alarm into.
3. If outlet is mounted sideways (horizontally),
rotate the plug and plug the alarm in.
When the unit is first powered, the voice message "Push
Test Button!" will be played.
Note: This model is equipped with a feature that automatically activates the
battery backup when the alarm is plugged into an AC outlet for the first time.
CAUTION: Do not rotate the alarm while it is plugged into an outlet,
!
as damage to plug may result.
Important Labels Provided
Two labels have been provided that have important information on what to
do in case of an alarm. Add the phone number of your emergency service
provider in the space provided. Place one label next to the alarm after it is
mounted, and one label near a fresh air source such as a door or window.

5. Alarm Characteristics

Carbon Monoxide Alarm Indicator
When the alarm senses a dangerous level of CO, the unit will emit a loud
alarm pattern. The alarm pattern is 4 quick beeps followed by the voice
message "Warning, Carbon Monoxide!", then 4 quick beeps without the
voice message. This pattern; 4 beeps, voice message, 4 beeps, no voice
message, will repeat as long as dangerous CO conditions exist. The red
Alarm LED will flash the same pattern as the 4 quick beeps and the PPM will
be displayed on the digital display.
The digital display will be brightly lit if the unit is in alarm.
!
WARNING: If at any time you test the alarm and it does not perform as
described, have it replaced immediately.

6. Operating Characteristics

When you first power up the alarm: The red Alarm LED will light and the
alarm will chirp once, followed by the voice message; "Push Test Button".
CO alarm power indicators:
AC - Digital display constantly on.
DC Only - Green LED flashes briefly once every 60 seconds.
Within a few minutes, your carbon monoxide alarm will start monitoring
for CO and will continue to do so as long as it receives power.
Whenever the KN-COP-DP-10YB is operating, the digital display will display "0"
(with AC applied) to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the digital display will alternate between "CO" and the
measured CO concentration in parts per million (PPM), and the alarm will emit an
audible alarm pattern with the voice message "Warning, Carbon Monoxide!".