Electrical connection
Connection to wall junction box, alternatively to stand-
ard socket
Fig. 10
Electrical connection
RTH Room thermostat (accessories)
Commissioning and instructing the user
Commissioning and user instruction must be carried
out by the contractor performing the installation. The
operator must be instructed as to how the radiant
heater works and in particular be informed about the
minimum clearances to be observed.
8
(cont.)
1. On the installation side, install an omnipolar isola-
tor with a contact opening width of at least 3 mm in
the permanent electrical installation in accordance
with the installation regulations.
2. Correctly connect the supplied connecting cable
with plug to the junction box.
Note
The connecting cable can be extended with a
cable of type H05VV-F3G 1.5 mm².
A direct connection to the appliance is not possi-
ble.