  • Page 1: Operating Instructions

    VIESMANN Operating instructions for the system user Direct electric heating for rapid heating of living spaces VITOPLANAR EC4 Please keep safe. 5855582 GB 2/2018...
  • Page 2 Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Danger Note This symbol warns against the risk of injury. Details identified by the word "Note" contain additional information. Please note This symbol warns against the risk of material losses and environmental pollution.
  • Page 3 Safety instructions Safety instructions (cont.) Auxiliary components, spare and wearing parts Please note Components that were not tested with the appli- ance may cause appliance damage, or may affect its functions. Installation or replacement work must only be carried out by a qualified contractor. Information on operation Danger Please note...
  • Page 4: Table Of Contents

    Index Index Introductory information Symbols ....................Intended use ..................Product information ................Permissible ambient conditions ............. Clearance dimensions ................ ■ Commissioning ..................Commissioning the appliance ............. ■ Operation Summary of controls and indicators ............How to use the controls ................. Locking the buttons ................
  • Page 5: Symbols

    Intended use presupposes that a permanent installa- tion in conjunction with permissible components designed for this purpose has been carried out. Product information Vitoplanar EC4 The electronic controller ensures that the required ■ temperature is maintained. Type Output in kW ■...
  • Page 6: Permissible Ambient Conditions

    Introductory information Permissible ambient conditions Clearance dimensions Please note If the appliance is operated without maintaining the minimum clearances, flammable objects may catch fire. Observe the specified minimum clearances. For safety reasons, the following minimum clearances from furniture and flammable objects must be observed: ■...
  • Page 7: Summary Of Controls And Indicators

    Operation Summary of controls and indicators The controls are located at the top right. Fig. 3 ON/OFF switch Fig. 2 Heating No heating Display "Heating mode" LED Note "Prog" LED The ON/OFF switch does not disconnect the appli- Increase temperature button/next ance from the power supply.
  • Page 8: Switching The Appliance On

    Start-up/shutdown Switching the appliance on Danger Turn on the appliance at the ON/OFF switch (switch If the surface of the appliance or the power position 1). Then select the operating mode; see chap- cable with the ON/OFF switch is damaged, there ter "Selecting the operating mode".
  • Page 9: Selecting The Operating Mode

    Room heating Selecting the operating mode Operating modes Press MODE repeatedly until the required operating mode is displayed. Operating mode Display Meaning Standard mode Set temperature Heating with the set temperature Reduced mode "EC" Heating with temperature re- duced by 3 °C Frost protection "HG"...
  • Page 10 Room heating Day programs (cont.) How the days of the week are shown 3. Use to select the required day program. "LU" Monday "MA" Tuesday 4. Confirm with MODE. "ME" Wednesday "JE" Thursday 5. Repeat steps 3 and 4 for the other days. "UE"...
  • Page 11: Further Adjustments

    Further adjustments "Open window" function This function stops heating mode automatically if a Activating/deactivating the function sudden drop in temperature is detected. "FE" is dis- played. Press MODE for 10 seconds. To reactivate heating mode, press MODE. "F0" Function deactivated "F1"...
  • Page 12: Appliance Does Not Heat

    What to do if... Appliance does not heat Cause Remedy Appliance is switched off. Switch the appliance on. Set temperature on the room thermostat is lower than Change the set temperature on the room thermostat. the actual temperature in the room. Standard mode is not activated.
  • Page 13: Maintenance

    Maintenance Maintenance The heater is maintenance-free. Cleaning Please note Please note If the appliance is cleaned while hot, it may be Incorrect cleaning agents (e.g. scouring agents) damaged. may damage the surfaces of the appliance. Allow the heater to cool down completely before Only use suitable cleaners to clean the surfaces.
  • Page 14: Information On Disposal

    (Altstoff Recycling Austria AG, licence num- ber 5766). Final decommissioning and disposal of the heater Viessmann products can be recycled. The heater does Speak to your contractor about the correct disposal of not belong in the household waste. your old system.
  • Page 16 Your contact Contact your local contractor if you have any questions about your system or wish to arrange maintenance or repair work. You can find local contractors on the internet at www.viessmann.de. Viessmann Werke GmbH & Co. KG Viessmann Limited...