Setup
2
Battery Backup Internet Connection and
Alerts Configuration
Before setting up the Link
O, make sure your Battery
2
Backup Unit - MBSP-3 is installed correctly, refer to Own-
er' s Manual for instruction. Make sure the primary pump
and battery backup unit has power. Verify the system is
operational by pressing the 'TEST SYSTEM' button and
observing the test sequence.
1.
Find an open network connection on your internet
router or other hard-wired connection. Rotate the
antennae up on the gateway.
NOTICE: We recommend the use of an uninterrupted
power supply for your internet modem, home router
and the gateway power supply.
2. Using the supplied 1 meter Ethernet cable (or longer
cable if necessary), connect the gateway to an open
network port.
3. Connect the gateway power supply to a 115 VAC outlet,
plug into the back of the gateway.
The LED will blink red for a few seconds.
When the LED becomes solid green or solid green
with an occasional blink your gateway is con-
nected to the VWA servers.
If not, refer to Gateway Troubleshooting.
4. Once the gateway LED is green, go to the BBU and
verify that the AC power LED is solid green. If not, the
gateway will have to be moved closer to the BBU.
5. Log onto the website www.mylink2o.com
Select "Sign Up"
Follow the online instructions and enter the
required personal information to create a user
account. The Alerts will use the e-mail addresses
and phone numbers entered here.
Enter the Unique Device ID Key included with the
MBSP-3 - located on BBU case and manual cover.
6. Test installation by clicking the "Test" icon on the web
page and verify the unit has run the test.
7.
Refer to the Link
O website to set alerts.
2
8. Alerts can be tested by activating the pump with the
float switch.
10