Power Supply; Safety; Physical - Cabletron Systems MR-9T Installation Manual

802.3 10base-t multiport repeater
Table of Contents

Advertisement

SPECIFICATIONS/REQUIREMENTS

Power Supply

Input Power USA:
Input Power UK:
Input Power Europe:
Output Power:
Operating Temperature
Range:
Note: The power source for the MR9 is to be certified for use in the
country of installation with a SELV output of 15V DC and capable of
providing a minimum of 900mA. The output connector is to be
compatible with TOTAL POWER or MORFOR RJ-01-E connectors.
Environment
Operating Temperature:
Heat Output:
Storage Temperature:
Operating Humidity:

Safety

Designed in accordance with UL478, UL910, NEC 725-2(b), CSA,
IEC, TUV, VDE Class A. Meets FCC part 15 Class A limits.
Warning: It is the responsibility of the person who sells the system to
which the MR9 will be a part to ensure that the total system meets
allowed limits of conducted and radiated emissions.

Physical

Dimensions:
Weight
MR9:
15 Vdc adapter:
Page 2-4
90 - 135 Vac, 50-60 Hz at 19.0 W
216 - 264 Vac, 50 Hz at 13 W
180 - 240 Vac, 50 Hz at 13 W
0.9 amp at 15 Vdc
0 to 70 C
+5 to +40 C
64.9 Btu/Hr
-30 to +90 C
5 to 95% (non-condensing)
10.16 x 17.78 x 2.28 cm (4 x 7 x .9 in)
363 gm (0.8 lb)
409 gm (0.9 lb)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr9t-c

Table of Contents