Cooling Mode Operation
Heating Mode Operation
a) After the unit is connected to
power supply, the air conditioning unit
shall enter the operating status if you
press the ON/OFF key
b) Press the mode key and select the
(
) mode
c) Press the temperature key and set
the temperature as required
a) After the unit is connected to
power supply, the air conditioning unit
shall enter the operating status if you
press the ON/OFF key
b) Press the mode key and select the
(
) mode
c) Press the temperature key and set
the temperature as required
Connect the unit to power supply. Press the "ON/OFF"key.
Press the "MODE" key to select "Cooling" mode. Use the
"Temperature" key to adjust the set temperature for the
room.
Connect the unit to power supply. Press the "ON/OFF"key.
Press the "MODE" key to select "Heating" mode. Use the
"Temperature" key to adjust the set temperature for the
room.. Under the heating mode, the unit has the functions
of preventing cold air supply and supplying remaining heat.
After the startup of the compressor, the indoor fan shall
start operation when the evaporator temperature is larger
or equals 35 or after the unit has be started for 45 secon-
ds, so as to avoid supply of cold air shortly after the unit is
started. After the stop of the compressor, the indoor fan
shall stop operation after supplying air for 120 seconds.
13