Optional Flow Conditioners (For Insertion Flow Meter Applications) - Sage SIE Series Operation And Instruction Manual

Thermal gas mass flow meter
Table of Contents

Advertisement

38
S A G E M E T E R I N G , I N C .
Optional Captive Flow Conditioners
Largest of the
Two Perforated
Plates
Gaskets
1 Insertion Flow Meters need to be calibrated for Flow Conditioners; either order Flow Conditioners at
same time as Insertion flow meter, or use suffix FC1DIACAL in the flow meter Part Number.
REV. 03-SIE/SRE
ANSI Class Flanges
(user supplied)
FLOW
O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
(FOR INSERTION FLOW METER APPLICATIONS
FRONT VIEW OF ONE OF THE CONDITIONING PLATES
One Pipe
Diameter
Flow Conditioning
Assembly is
inserted here.
NOTE: The larger of the two perforated plates
of the Sage conditioning basket is positioned
between two flanges and two gaskets as shown.
The smaller of the two perforated plates of the
conditioner will freely slide into the application
pipe, facing downstream. The compression will
be placed one diameter downstream of the
downstream plate.