O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l

CAPTIVE FLOW CONDITIONERS

Can Be Installed in Conjunction with Insertion Style Flow Meters
IMPORTANT The location of the probe must be exactly one pipe ID diameter (i.e., 4" in a 4" pipe; 6" in
a 6" pipe, etc.) downstream of the Captive Flow Conditioning assembly. The Captive Flow Conditioners
are always designed to be separated by one pipe diameter. See drawing below. The probe location must
be one pipe ID diameter downstream of Flow Conditioner, or errors will occur.
Note: See table on page 11
(last Column) for Straight Run
Requirement
Largest of the
Two Perforated
Plates
Gaskets
One Pipe
Diameter
Straight Run Requirement
from this Flange
FLOW
ANSI Class Flanges
(user supplied)
NOTE: The larger of the two perforated plates of the Sage
Flow Conditioning assembly is positioned between two flanges
and two gaskets as shown. The smaller of the two perforated
plates of the conditioner will freely slide into the application
pipe, facing downstream. The probe mounting hardware will be
placed one diameter downstream of the downstream plate.
Probe location must be one pipe ID diameter downstream of
Flow Conditioners or errors will occur.
S A G E M E T E R I N G , I N C .
Front View of one of the Conditioning Plates
One Pipe
Diameter
Flow Conditioning
Assembly is
inserted here.
13