0015-MSF-IFC Multi-Speed Cartridge Circulator
SUPERSEDES: June 1, 2014
Plant ID# 001-4002
APPLICATION:
• Maximum operating pressure is 125 psi (862 kPa).
• Maximum water temperature not to exceed nameplate rating.
• Cast iron circulators are to be used for closed loop systems only.
• Stainless steel circulators are to be used on open, potable water systems.
• Taco Cartridge circulator pumps are for indoor use only – employer uniquement a
l´interieur.
• For use with water or maximum of 50% glycol/water mix systems only.
WARNING: Do not use in swimming pool or spa areas; pump has not been investigated for this
application.
WARNING: In the event the electrical box has been pulled off of the housing, DO NOT attempt to
reattach it. Use of any other screw may short out the stator windings, creating a risk of
electrical shock.
CAUTION: When installing electrical connections, do not apply mechanical loads to the capacitor
box; otherwise, retaining screws may be pulled out of the housing, making circulator
unusable.
CAUTION: 1. The addition of petroleum based fluids or certain chemical additives to systems
utilizing TACO equipment voids the warranty.
2. Use supply wires suitable for 90°C – ATTENTION: Employer des fils d´alimentation
adequats pour 90°C.
WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main
electrical unit.
INSTALLATION:
1. Location – Install the "OO" circulator on the supply side of the boiler "pumping away" from the expansion tank as shown in
Figure 1. This is the best pump location for optimum system performance and maintaining positive system pressure. An alter-
nate location is on the boiler return line as shown in Figure 2.
CAUTION: Do not use flat rubber gaskets on pump flanges. Only use O-ring gaskets provided or
leaking will result. Warranty will be void.
2. Mounting position – Mount circulator with the motor in the horizontal position. It may be mounted vertically with the
motor up, provided that the system cold fill pressure is at least 20 psi (138 kPa) to ensure proper air purging and prevent
flashing.
3. Rotating body – Body has an arrow on the front that indicates direction of flow. To rotate body, remove the four body
bolts, rotate body and replace bolts. Make sure that the junction box is NOT located underneath the circulator. (The
junction box must NOT be located in the 6 o'clock position, as viewed from the motor end.)
4. Electrical connections – Observe all applicable codes when connecting to power supply.
The motor is thermally protected, and does not require additional overload protection.
Either colored wire from the capacitor box can be attached to either colored wire from the
power supply. There is no "hot" or "common" wire leading from the capacitor box. Typical
installation would be to attach the white wire to the white (common) power supply wire and
either the yellow or blue wire to the black (hot) power supply wire. The pump cannot run
backwards.
CAUTION: Installations at higher elevations over 5000 feet must have higher fill pressure of 20 psi
minimum to prevent pump cavitation and flashing. Premature failure may result. Adjust
expansion tank pressure to equal fill pressure. A larger size expansion tank may be required.
Instruction Sheet
with Integral Flow Check
102-433
EFFECTIVE: August 10, 2015
ELECTRICAL DATA
SPEED
Amps (Watts)
1
0.54 (58)
2
0.74 (79)
3
0.85 (98)

Advertisement

loading

Summary of Contents for Taco Comfort Solutions 0015-MSF-IFC

  • Page 1 Instruction Sheet 102-433 0015-MSF-IFC Multi-Speed Cartridge Circulator with Integral Flow Check SUPERSEDES: June 1, 2014 EFFECTIVE: August 10, 2015 Plant ID# 001-4002 APPLICATION: • Maximum operating pressure is 125 psi (862 kPa). • Maximum water temperature not to exceed nameplate rating.
  • Page 2 CAUTION: Never run circulator dry or permanent damage may result. 5. Fill system with tap water or maximum 50% glycol/water mix – The system must be filled before operating the circulator. The bearings are water lubricated and should not be allowed to operate dry. Filling the system will result in immediate lubrication of the bearings.
  • Page 3 3-Speed Models TACO Armstrong Grundfos Wilo B & G Astro-230-3 Star-S16F 0015-MSF-IFC * UPS15-58FC NRF-25 Astro-250-3 Star-S21F * Replaces Taco 00R-MSF-IFC 3-speed. PROPER REMOVAL/REPLACEMENT OF THE INTEGRAL FLOW CHECK (IFC) Your “00” circulator with an Integral Flow Check (IFC) is designed for easy removal, service and replacement.
  • Page 4 REPLACEMENT: Replacement IFC Kit: Part #0010-025RP 1. Make sure the IFC pocket is clean and free of any debris. 2. Position IFC into the machined pocket inside the casing as shown in Figure 4. Firmly press the IFC into the pocket until it snaps into place.