Manual Check Selection Mode - Daikin LXE10E-A18C Service Manual And Parts List

Marine type container refrigeration unit
Table of Contents

Advertisement

Available languages

Available languages

https://daikin-p.ru

12. MANUAL CHECK SELECTION MODE

The LED indicate the values of following items.
Compressor operating time, Evaporator fan motor high-speed running current, Evaporator fan motor
low-speed running current, Condenser fan motor running current, Battery life, Horse power, Elapsed
time after trip start, Evaporator fan motor running time, Condenser fan motor running time, Controller
software version and sensor calibration.
COMPRESSOR
OPERATING
TIME
EVAPORATOR FAN
MOTOR HIGH-SPEED
RUNNING CURRENT
EVAPORATOR FAN
MOTOR LOW-SPEED
RUNNING CURRENT
CONDENSER FAN
MOTOR RUNNNING
CURRENT
ELAPSED TIME
AFTER TRIP
START
EVAPORATOR
FAN MOTOR-1
OPERATING TIME
EVAPORATOR FAN
MOTOR-2
OPERATING TIME
CONDENSER FAN
MOTOR
OPERATING TIME
CONTROLLER
SOFTWARE
VERSION
SENSOR
CALIBRATION
To indicate the compressor operating time:
key while the LCD indicates "CC ✕10H".
Press the
The operating time is [the value indicated on the LED] ✕10 hours.
Pushing the
key for 3 seconds sets compressor operating time to 0 (hour).
To indicate the current value of evaporator fan motor high-speed operation:
Press the
key while the LCD indicates "EFH
the current value. (Unit: Ampere)
To indicate the current value of evaporator fan motor low-speed operation:
Press the
key while the LCD indicates "EFL
current value. (Unit: Ampere)
To indicate the current value of condenser fan motor running current:
Press the
key while the LCD indicates "CF A", then the LED indicates the
current value. (Unit: Ampere)
To indicate the elapsed time after trip start:
Press the
key while the LCD indicates "TS
elapsed time. (Unit: Hours).
When the
key is depressed for 3 seconds while the elapsed time is indicated,
the TRIP START is set, and the elapsed time display is reset to "0" (hour).
To indicate the evaporator fan motor-1 operating time:
key while the LCD indicates "EF1 ✕10H".
Press the
The operating time is [the value indicated on the LED] ✕10 hours.
When the
key is depressed for 3 seconds while the evaporator fan motor-1
operating time is indicated, the evaporator fan motor-1 operating time is reset to
"0" (hour).
("EF1" stands for the right hand side fan motor seeing from the inside of the container.)
To indicate the evaporator fan motor-2 operating time:
key while the LCD indicates "EF2 ✕10H".
Press the
The operating time is [the value indicated on the LED] ✕10 hours.
If the
key is depressed for 3 seconds while the evaporator fan motor-2
operating time is indicated, the evaporator fan motor-2 operating time display is
reset to "0" (hour).
"EF2" stands for the left hand side fan motor seeing from the inside of the container.
To indicate the condenser fan motor operating time:
key while the LCD indicates "CF ✕10H".
Press the
The operating time is [the value indicated on the LED] ✕10 hours.
If the
key is depressed for 3 seconds while the condenser fan motor operating time
display is indicated, the condenser fan motor operating time display is reset to "0" (hour).
To indicate the controller software version:
Press the
key while the LCD indicates "SOFTVER".
The value on the LED is the software version.
To calibrate the temperature sensor SS,RS,DSS or DRS ;
Press the
key while the LCD indicates "CAL".
(Refer "5.1 sensor calibration" for more detail.)
A", then the LED indicates
A", then the LED indicates the
H", then the LED indicates the
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lxe10e-a18d

Table of Contents