4. Battery

4.1 Specifications
Controller's battery depends on the models. Rechargeable (A35B).
The battery is positioned on CPU & I/O box in controller box.
Rechargeable: DAIKIN original rechargeable battery
4.2 Function
This battery is used without main power supply for the following functions.
1) Display wake up (Refer to chapter 3.3.2) page 3-11 of TR01-09C.
Setting/Display the following items on the LCD display.
<Display>
Temperature on the return air sensor
Temperature on the supply air sensor
<Setting change>
Inside temperature, defrosting interval, dehumidifying set, Unit ON/OFF
2) USDA data log
USDA sensors data log every 1 hour
Note) When the Alkaline battery is equipped, it must be replaced for a new every PTI, when USDA is
used.
3) Trip data log
Trip data; Setting point, Supply air, Return air, Humidity and time is logged every 1 hour after power off
until battery run out. (Min. 3 days)
4.3 Battery check
ß
Alkarine battery: Press
When the power is disconnneced.
Rechargeable battery: Press "Battery check meter"
Green: Battery is charged.
Red: Charge the battery.
No light: Charge or replace the battery.
key to confirm the Battery mode workabte.