3. Other Alarm Visual and Audible Indicators

Operational Mode
normal (standby)
test (button press when
no alarm condition is
present)
Smoke or CO Alarm
Memory (unit has expe-
rienced a smoke or CO
alarm event within the
last hour)
Smoke Alarm Hush®
Mode, (SMArt Hush®
COntrOl)
CO alarm reset
Smoke Alarm Hush®
Mode Canceled
Initiating Alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on continuously
during light conditions, or blink every 60 sec
during dark conditions.
DC power: Green LED blink approx every 60 sec.
4 patterns of Red/Amber/Green.
Test: Red LED blinks in time with
alarm pattern. Strobe flashes every
second during smoke alarm, and
4 times every 5 seconds during
CO alarm.
• Green LED fade on/off at test
complete
Red and Amber LED alternate on 1
sec, every 10 sec.
Red LED blinks every 2 sec.
None
None
Green LED blinks once per sec indicating that
this is the unit initiating the alarm in an inter-
connected, multiple alarm, system.Strobe
flashes in smoke or CO alarm pattern.
Audible Indications
Button press sound
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
3 long beeps, Voice "Fire!", 3 long
beeps, 4 quick beeps, Voice "Warning,
Carbon Monoxide," 4 quick beeps,
Voice "Test Complete," Power on/
reset sound.
Voice "Test Canceled" if button
pushed before test sequence begins.
After button push: "Smoke previously
detected" or "Carbon Monoxide
previously detected" only on the
initiating alarm unit.
After button push: "Hush® Mode Acti-
vated." Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush®: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
After button push: CO alarm pattern
stops.
Voice message "Hush® Mode
Canceled."
Unit in either Smoke or CO alarm
mode.
Action/Note:
Perform Test/Hush® button
press once a week to verify
proper alarm operation
* Push/release button before
the countdown ends to
cancel test.
Push test button to clear
Alarm Memory. NOTE: stan-
dard test sequence will follow.
(Push/release button again to
cancel test).
This feature is to be used
only when a known alarm
condition, such as smoke from
cooking, activates the alarm.
Unit is confirming if CO is
present or if it experienced a
nuisance situation. Re-alarm
means danger. Move to fresh
air and call 911.
When smoke levels drop
below the alarm threshold,
the voice message "Hush®
Mode Canceled" will occur .
During alarm, the Initiating
Alarm green blinks will occur
in between the red blinks.