Configuration
CF08 – Open detection function
0
1
If the receiver is combined with an open detector (e.g. for a
window), the heating is switched to frost protection mode when
the window is opened.
CF09 – Presence detection function
0
1
If the receiver is combined with a motion detector, the temperature
is automatically reduced during long periods of absence:
• 1.5 hours -> current set temperature -1.5 °C
• 3.5 hours -> current set temperature -3.5 °C
• 48 hours -> set frost protection temperature
CF10 – Max. set comfort temperature
Adjustable from 22 °C to 30 °C.
Standard value: 28 °C
CF11 – Programming format
0
1
10
(continued)
Deactivated
Activated
Deactivated
Activated
Programming in 1-hourly steps
Programming in 1/2-hourly steps