BUSCH R5 RU 0050 B Instruction Manual

BUSCH R5 RU 0050 B Instruction Manual

Rotary vane vacuum pumps
Hide thumbs Also See for R5 RU 0050 B:

Advertisement

Quick Links

Instruction Manual
R5
Rotary Vane Vacuum Pumps
RU 0050 B, RU 0070 B
0870167126/A0002_en / Original instructions / Modifications reserved
16/09/2021

Advertisement

Table of Contents
loading

Summary of Contents for BUSCH R5 RU 0050 B

  • Page 1 Instruction Manual Rotary Vane Vacuum Pumps RU 0050 B, RU 0070 B 0870167126/A0002_en / Original instructions / Modifications reserved 16/09/2021...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents 1 Safety ............................3 2 Product Description ........................4 2.1 Operating Principle ......................5 2.2 Application........................5 2.3 Standard Features ......................5 2.3.1 Variable-Frequency Drive ..................5 2.3.2 LED-Display......................5 2.3.3 I/O and Communication Port ................5 2.4 Optional Accessories ......................
  • Page 3: Safety

    Safety Prior to handling the machine, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change anything on the product.
  • Page 4: Product Description

    2 | Product Description Product Description LED "A1" Axial fan I/O and communication port Eye bolt Exhaust filter Suction connection LED-display (A1 only) Mains conection Nameplate Oil drain plug Oil fill plug Oil separator Oil sight glass Discharge connection Variable frequency drive NOTE Technical term.
  • Page 5: Operating Principle

    Conveying of other media leads to an increased thermal and/or mechanical load on the machine and is permissible only after a consultation with Busch. The machine is intended for the placement in a non-potentially explosive environment. The machine is designed for indoor installation, in case of outdoor installation, ask your Busch representative in order to take specific precautions.
  • Page 6: Optional Accessories

    2 | Product Description 2.4 Optional Accessories 2.4.1 PC-Software For parameter settings with personal computers a PC-software and appropriate connec- tion cable can be provided. 2.4.2 Manual Control Unit Control panel can be used for simply controlling the machine and parameter setting in the field.
  • Page 7: Transport

    Transport | 3 Transport WARNING Suspended load. Risk of severe injury! • Do not walk, stand or work under suspended loads. WARNING Lifting the machine using the motor eye bolt. Risk of severe injury! • Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as shown.
  • Page 8: Storage

    4 | Storage Storage • Seal all apertures with adhesive tape or reuse provided caps. NOTICE Long storage time. Risk of damage to the machine! • Due to a long storage time the capacitors of the variable-frequency drive can lose effi- ciency because of electrochemical processes.
  • Page 9: Connecting Lines / Pipes

    • Make sure that all provided covers, guards, hoods, etc. are mounted. If the machine is installed at an altitude greater than 1000 meters above sea level: • Contact your Busch representative, the motor should be derated or the ambient temperature limited.
  • Page 10: Filling Oil

    Risk of premature failure! Loss of efficiency! • Only use an oil type which has previously been approved and recommended by Busch. For oil type and oil capacity see Technical Data [► 22] and Oil [► 22]. 1x o-ring, part no.: 0486 000 590...
  • Page 11: Electrical Connection

    • Make sure that the motor of the machine will not be affected by electric or electro- magnetic disturbance from the mains; if necessary seek advice from Busch. • Make sure that the EMC-class of the machine confirms with the requirements of your supply network system, if necessary provide further interference suppression (EMC- Class of the machine see Technical Data [► 22]).
  • Page 12: I/O And Communication Port Schematic

    "Logic 0" ► input voltage = 0 … 4 VDC "Logic 1" ► input voltage = 8 … 30 VDC Communication port via Modbus (RS485): Ask your Busch representative for more information. Commissioning NOTICE The machine can be shipped without oil.
  • Page 13: Continuous Operation

    Commissioning | 6 NOTICE Frequent starts and stops by connecting and disconnecting from the power supply. Risk of damage to the machine! Starting the machine by connecting and disconnecting the power supply is permitted max. 1x per minute. Between disconnecting and connecting at least 10 seconds must have been passed.
  • Page 14: Maintenance

    Risk of injuries! Risk of premature failure and loss of efficiency! • Respect the maintenance intervals or ask your Busch representative for service. • Shut down the machine and lock against inadvertent start up. • Vent the connected lines to atmospheric pressure.
  • Page 15: Maintenance Schedule

    Weekly • Check the oil level, see Oil Level Inspection [► 15]. • Check the machine for oil leaks - in case of leaks have the machine repaired (contact Busch). Every 6 months • Clean the machine from dust and dirt.
  • Page 16: Oil Change

    NOTICE Use of an inappropriate oil. Risk of premature failure! Loss of efficiency! • Only use an oil type which has previously been approved and recommended by Busch. 1x o-ring, part no.: Drain pan 0486 000 505 16 / 28...
  • Page 17: Exhaust Filter Change

    Maintenance | 7 For oil type and oil capacity see Technical Data [► 22] and Oil [► 22]. 1x o-ring, part no.: 0486 000 590 Check oil level 7.4 Exhaust Filter Change 10 mm wrench Instruction Manual R5 RU 0050-0070 B_EN_en 17 / 28...
  • Page 18: Overhaul

    • Decontaminate the machine as much as possible and state the contamination sta- tus in a ‘Declaration of Contamination’. Busch will only accept machines that come with a completely filled in and legally binding signed ‘Declaration of Contamination’ (form downloadable from www.buschvacuum.com).
  • Page 19: Dismantling And Disposal

    Use of non-Busch genuine spare parts. Risk of premature failure! Loss of efficiency! • The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty. Spare parts kit Description Part no.
  • Page 20: Troubleshooting

    The motor or the variable • Check the LED on the frequency drive (VFD) is de- variable frequency drive fective. display, if red, it is faulty (contact Busch or read error with software). The coupling (CPL) is defec- • Replace the coupling tive. (CPL).
  • Page 21: Circuit Diagram

    Circuit Diagram | 12 12 Circuit Diagram Instruction Manual R5 RU 0050-0070 B_EN_en 21 / 28...
  • Page 22: Technical Data

    13 | Technical Data 13 Technical Data RU 0050 B RU 0070 B Nominal pumping speed (60Hz) m³/h Ultimate pressure hPa (mbar) abs. 0.05 Nominal motor rating (60Hz) Nominal current for 1~ 200-240 V ±10% Internal main fuse (TT type) Max.
  • Page 23 Oil | 14 Instruction Manual R5 RU 0050-0070 B_EN_en 23 / 28...
  • Page 24: Eu Declaration Of Conformity

    This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.
  • Page 25 EU Declaration of Conformity | 15 In case control systems are integrated. Legal person authorized to compile the technical file Busch Dienste GmbH and authorized representative in the EU Schauinslandstr. 1 (if the manufacturer is not located in the EU): DE-79689 Maulburg Maulburg, 18.08.2021...
  • Page 26: Declaration Of Conformity

    This Declaration of Conformity and the UKCA-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the UKCA-mark.
  • Page 27 UK Declaration of Conformity | 16 Legal person authorized to compile the technical file Busch (UK) Ltd and importer in the UK 30 Hortonwood (if the manufacturer is not located in the UK): Telford - UK Maulburg, 18.08.2021 Dr. Martin Gutmann...
  • Page 28 Busch Vacuum Solutions We shape vacuum for you. Argentina Denmark Malaysia South Africa info@busch.com.ar info@busch.dk busch@busch.com.my info@busch.co.za Australia Finland Mexico Spain sales@busch.com.au info@busch.fi info@busch.com.mx contacto@buschiberica.es Austria France Netherlands Sweden busch@busch.at busch@busch.fr info@busch.nl info@busch.se Bangladesh Germany New Zealand Switzerland sales@busch.com.bd info@busch.de sales@busch.co.nz...

This manual is also suitable for:

R5 ru 0070 b

Table of Contents