Electrical Connection; Control Display - HBC-Radiomatic FSE 511 Operating Instructions Manual

Table of Contents

Advertisement

Pos : 22 /T echnisc he Dokumentation/Betriebsanl eitungen/Empfänger/Elektrischer Ans chl uss - Kontroll-Lampenfeld @ 10\mod_1398244692035_48.doc x @ 122060 @ 11 @ 1

Electrical Connection

Depending on the version, the radio receiver is connected to the machine electronics either via a cable
gland or with a Harting plug connection.
Please observe that the receiver may only be connected to the supply voltage indicated on the type plate !
Warning – shock hazard!
The electrical connection may only be carried out by skilled personnel .
The electrical connection must comply with the enclosed wiring diagram .
Switch off the supply voltage before opening the receiver. There is a risk of fatality from touching
live parts inside the housing!

Control Display

A control display with LEDs indicating the operating stat us of the radio system is located in the upper
housing part.
The LEDs have the following meaning:
Control display
Meaning
Color
On
yellow
RF
red
Si1
green
Si2
green
Feedback
yellow
Control display
Meaning
Color
On
yellow
RF
red
Si1
green
Si2
green
Feedback
yellow
Pos : 23 /T echnisc he Dokumentation/Betriebsanl eitungen/Allgemei n/----- Sei tenumbr uch ------ @ 1\mod_1219672326234_0.doc x @ 29509 @ @ 1
(Data are only transmitted from the transmitter to the receiver.)
Receiver
Illuminates as soon as the receiver is connected to the supply voltage.
Illuminates as soon as the radio connection is interrupted.
Illuminates as soon as the E-STOP relays are closed.
Illuminates as soon as a drive command is output.
Off.
(Not available for FSE 508 / 509 / 512.)
(Data are transmitted in both directions.
Non-safety-relevant data are transmitted in the feedback.)
Receiver
Illuminates as soon as the receiver is connected to the supply voltage.
Illuminates as soon as the radio connection is interrupted.
Illuminates as soon as the E-STOP relays are closed.
Illuminates as soon as a drive command is output.
Illuminates as soon as a feedback telegram is transmitted.
(Not available for FSE 508 / 509 / 512.)
Simplex procedure
Duplex procedure
7 / 13