FMS-1655 Room Pressure Remote Display
Installation and Programming Manual
LB-FMS1655-RS
LB-FMS1655-RT
Application
These installation instructions guide the installer through the installation of the FMS-1655 Room Pressure Remote
Display. Please read these instructions thoroughly before beginning installation.
North American Emissions Compliance
United States
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful
interference, in which case users will be required to correct the interference at their own expense.
Canada
This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
Installation
NOTICE
Risk of Property Damage.
Ensure that the power source conforms to the requirements of the equipment. Failure to use a correct power
source may result in permanent damage to the equipment.
NOTICE
Risque de dégâts matériels.
S'assurer que la source d'alimentation électrique est conforme aux spécifications de l'équipement. L'utilisation
d'une source d'alimentation électrique inappropriée risque d'endommager irrémédiablement l'équipement.
IMPORTANT:
The FMS-1655 Room Pressure Remote Display must be wired to 24 VAC only. Wiring the unit to
110 VAC will cause serious damange and void the warranty.
Use of the software that is in (or constitutes) this product or access to the cloud or hosted services applicable to this product,
if any, is subject to applicable terms set forth at www.johnsoncontrols.com/techterms. Your use of this product constitutes an
agreement to such terms. If you do not agree to be bound by such terms, you may return the unused product to your place of
purchase.
Code No. LIT-12013124 Rev. A
Remote Display
Central Monitoring Station
The Next Generation in Critical Airflow Controls
Issued August 2018
JCI FMS-1655R
JCI CMS-1655
JCI FMS-1655

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LB-FMS1655-RS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Johnson Controls LB-FMS1655-RS

  • Page 1 FMS-1655 Room Pressure Remote Display Installation and Programming Manual LB-FMS1655-RS Code No. LIT-12013124 Rev. A LB-FMS1655-RT Issued August 2018 Application These installation instructions guide the installer through the installation of the FMS-1655 Room Pressure Remote Display. Please read these instructions thoroughly before beginning installation.
  • Page 2: Table Of Contents

    INSTALLATION AND PROGRAMMING MANUAL Table of Contents INSTALLATION MANUAL Introduction…………………………………………………...……………………………………………………………………..………….1 Mounting Procedure: Flush Thin Mount……..............................…2 Mounting Procedure: Surface Mount………..…………………...………………………………………………………………………………2 Quick Start Guide…………………………………………………...…………………………………………………………………………...…3 Main Display Screen...………………………………………...…………………………………………………………..…………………4 Configuring the FMS-1655R..……………………………...……………………………………………………………..…………………4 Specifying Network Address(es)...…..…………………...……………………………………………………………..…………………5 Selecting the Individual Parameter...………………………...……………………………………………………………..…………………5 Adding Password Security…………………………………...……………………………………………………………..…………………5 Changing Display Settings...………………………………...……………………………………………………………..…………………6 Wiring the FMS-1655R to Nearest JCI Controller....……………………………………………………………..…………………7 Notes....………………………………………...………..……………………………………………………..…………………8 PROGRAMMING MANUAL...
  • Page 3 INSTALLATION AND PROGRAMMING MANUAL Specifications FMS-1655R Remote Display Monitoring Capacity..…………………………………………............…….…One FMS-1655 Room Pressure Controller Interface Cable ……………….……………………………………………………………………………………………… Belden 3107A, 22 AWG minimum Protocol..……………………………………………………………………………………………………………..JCI Proprietary (RS-485 interface) Power (may be supplied by FMS-165x or by separate power supply)………………………………………………………………………… 18 to 32 Vdc Touchscreen User Interface LCD Size and Type..……………………………………………………………………………………………………………………...
  • Page 4: Installation Manual

    INSTALLATION MANUAL Introduction • Password protection (up to 10 entries) The user may set up multiple passwords to The JCI FMS-1655R Remote Display is used prevent unauthorized or casual access to the to remotely display any parameter monitored • Protocol-independent solution; works FMS-1655R configuration settings.
  • Page 5: Mounting Procedure: Flush Thin Mount

    INSTALLATION MANUAL SUBHEAD Mounting Procedure: Flush Thin Mount 4. Remove the paper backing from the two subnet connections should be terminated The FMS-1655R flush thin mount model offers adhesive strips on the retrofit mounting at NETWK+ and NETWK- at the 3-position an attractive stainless steel faceplate with an plate and insert it into the cut opening of the terminal block (see page 7).
  • Page 6: Quick Start Guide

    INSTALLATION MANUAL The electrical connections to the FMS-1655R two drywall anchors to mount the surface 7. With the electrical connections properly are made via convenient terminal block mount Safety Halo backplate. Using the terminated, the surface mount enclosure connectors as shown on page 7.
  • Page 7: Main Display Screen

    INSTALLATION MANUAL SUBHEAD with the green checkmark action icon (Figure The FMS-1655R incorporates a full-color 6) indicates that the monitored parameter is touchscreen display and with an intuitive within normal operating range. menu system that allows the user to quickly setup the remote display for immediate use.
  • Page 8: Specifying Network Address(Es)

    SUBHEAD INSTALLATION MANUAL Specifying the Subnetwork Address To specify the subnetwork address of the companion FMS-1655, select the Monitor Setup option on the Unit Setup menu (see Figure 9). Use the address slider to specify the subnetwork address of the companion FMS-1655.
  • Page 9: Changing Display Settings

    INSTALLATION MANUAL The specified brightness setting is stored in Changing Display Settings The FMS-1655R display screen may be non-volatile memory and remains in effect customized using the options on the Display through a power cycle. Setup menu. The settings for the Safety Halo™...
  • Page 10: Wiring The Fms-1655R To Nearest Jci Controller

    INSTALLATION MANUAL Wiring FMS-1655R to Nearest JCI Controller Due to continuous improvement, JCI reserves the right to change product specifications without notice.
  • Page 11: Notes

    INSTALLATION MANUAL Notes Due to continuous improvement, TRIATEK reserves the right to change product specifications without notice. Due to continuous improvement, JCI reserves the right to change product specifications without notice.
  • Page 12: Programming Manual

    PROGRAMMING MANUAL Introduction This section details all of the available capabilities in the FMS-1655R, and should be used to access more detailed information regarding the menu options: • Overview • Main Setup Menu • Unit Setup • System Setup • Display Setup •...
  • Page 13: Unit Setup

    PROGRAMMING MANUAL SUBHEAD Unit Setup address of the companion FMS-1655 room At this screen, the user may specify the The FMS-1655R is capable of displaying any controller and select the Viewing Mode option: operating mode for the alarm buzzer, Audible of the six parameters being monitored by the Standard View or Status-only View.
  • Page 14: System Setup

    PROGRAMMING MANUAL There are also two additional action icons that When Auto-clean mode at the companion represent Neutral and Auto-clean mode at the FMS-1655 is enabled, the FMS-1655R companion FMS-1655 controller. indicates the status by a cyan background and a simulated fan as the action icon. The Normal status indicates that the monitored Safety Halo™...
  • Page 15: Managing System Security Passwords

    PROGRAMMING MANUAL SUBHEAD Managing System Security Passwords Configuring the Safety Halo™ The FMS-1655R incorporates a system The Safety Halo™ option on the Display security password facility to prevent Setup menus allows you to configure the unauthorized access to the system menus settings for the Safety Halo™...
  • Page 16: Selecting Display Mode

    PROGRAMMING MANUAL Selecting Display Mode automatically appears while entering the time. After entering the digits for the current time, The Display Mode option on the Display Similarly, the forward slash appears between touch the A/P button to specify am or pm, and Setup menu allows the subnetwork address of the month, day and year automatically while then touch the Next button to enter the date.
  • Page 17: Resetting The Fms-1655R

    PROGRAMMING MANUAL SUBHEAD invokes the information splash screen shown This option may be useful during the in Figure 27, including the electronic serial installation process when changes have been number, firmware version numbers, and the made to the network parameters (subnetwork subnetwork address of the companion FMS- address).
  • Page 18: User Menu Flow Diagram

    PROGRAMMING MANUAL User Menu Flow Diagram Due to continuous improvement, JCI reserves the right to change product specifications without notice.
  • Page 19 FMS-1655 Room Pressure Remote Display Installation and Programming Manual LB-FMS1655-RS Code No. LIT-12013124, Rev. A LB-FMS1655-RT Issued August 2018 +1-414-524-1200 Johnson Controls 5757 N. Green Bay Ave. P.O. Box 591 Milwaukee, WI 53201 JCI CMS-1655 Central Monitoring Station JCI FMS-1655 The Next Generation in Critical Airflow Controls Due to continuous improvement, TRIATEK reserves the right to change product specifications without notice.

This manual is also suitable for:

Fms-1655Lb-fms1655-rt

Table of Contents