Omega DP18-P9 Quick Start Manual

Omega DP18-P9 Quick Start Manual

Differential process indicator

Advertisement

Quick Links

An OME GA Te c h n o l o g i e s Co m p a n y
DP18 Series
Model DP18-P9
Differential Process Indicator
INSTRUCTION
SHEET
INSTRUMENT TO READ THE DIFFERENCE BETWEEN TWO PROCESS SIGNALS AND DISPLAY IN
ENGINEERING UNITS.
SIGNALS CAN BE : 0-20 mA. or 4-20 mA.
SPECIFICATIONS
DISPLAYS . . . . . . . . . . . . . . . . . . . . . . 3
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . 0.56" (14.2 mm.)
SYMBOLS . . . . . . . . . . . . . . . . . . . . . . ± 1.8.8.8
DECIMAL POINTS . . . . . . . . . . . . . . . . Selectable by jumpers
OVERRANGE INDICATION . . . . . . . . . Display flashes 1999
INPUT CONFIGURATION . . . . . . . . . . . Bipolar single
ZERO . . . . . . . . . . . . . . . . . . . . . . . . . Automatic
SPAN ADJUSTMENT . . . . . . . . . . . . . . ± 5 %
CONVERTER . . . . . . . . . . . . . . . . . . . . Dual-slope, average value
POLARITY . . . . . . . . . . . . . . . . . . . . . . Automatic ±
SIGNAL INTEGRATION PERIOD . . . . . 80 ms.
READ RATE . . . . . . . . . . . . . . . . . . . . 3.12 / sec.
HOLD . . . . . . . . . . . . . . . . . . . . . . . . . Optional
NOISE REJECTION NMR . . . . . . . . . . . 50 dB. 50/60 Hz.
ACCURACY . . . . . . . . . . . . . . . . . . . . 0.15 % ± 1 count
WARMUP TO RATED ACCURACY . . . 2 minutes
SPAN TEMPCO . . . . . . . . . . . . . . . . . . 100 ppm.
ZERO TEMPCO . . . . . . . . . . . . . . . . . . 2.5 µV/°C.
OPERATING TEMPERATURE . . . . . . . 0 to 50 °C (32 to 122 °F)
STORAGE TEMPERATURE . . . . . . . . . -40 to 80 °C (-40 to 176 °F)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . 310 gr. (0.68 lb)
CASE MATERIAL . . . . . . . . . . . . . . . . ABS, DIN 43700, black color
STANDARD POWER . . . . . . . . . . . . . . 115 Vac. ± 10 %, 50/60 Hz.
POWER CONSUMPTION . . . . . . . . . . . 5.5 VA for AC.
ELECTRICAL CONNECTIONS . . . . . . . Push-in cable connectors
BURN-IN . . . . . . . . . . . . . . . . . . . . . . . 24 h.
FIG. 3
TRANSDUCER "A"
Signal high
A
Signal low
Signal high
B
Signal low
TRANSDUCER "B"
THIS SIGNAL CONDITIONER INPUT ALLOWS THE DISPLAY IN ENGINEERING UNITS OR PERCENTAGES, THE DIFFERENCE BETWEEN TWO
PROCESS SIGNALS OF 0-20 mA OR 4-20 mA.
SIGNAL INPUT "A" MUST CORRESPOND, THEORETICALLY TO THE HIGHER SIGNAL,IN ORDER THAT THE DISPLAY READING BE POSITIVE.
IF THE SIGNAL "B" IS HIGHER THAN "A", THE DISPLAY READING WILL BE NEGATIVE.
CLOSE THE APPROPRIATE DECIMAL POINT JUMPER (FIG.5), CORRESPONDING TO THE RANGE SELECTED.
M2113/1294
½
digits, 7 segment, red LED
out
out
FIG. 1
SPAN : ADJUST THE MAXIMUM READING.
OFFSET : NOT IN SERVICE
SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR.
FIG. 2
Isolated digital output
(option)
SIGNAL
INPUT
ANALOG OUTPUT
(OPTION)
HOLD,
latch the reading
display, while these pins
are linked
ZERO ADJUST
C
B
A
SIGNAL CONDITIONER
CCD1294APC1B
FRONT VIEW
SPAN
OFFSET
REAR VIEW
Setpoint R1
Setpoint R2
(option)
(option)
D
C
1
10
B
A
+
-
POWER SUPPLY
see instrument label
SPAN ADJUST
COMPONENTS VIEW

Advertisement

loading

Summary of Contents for Omega DP18-P9

  • Page 1 An OME GA Te c h n o l o g i e s Co m p a n y DP18 Series Model DP18-P9 Differential Process Indicator INSTRUCTION SHEET M2113/1294 INSTRUMENT TO READ THE DIFFERENCE BETWEEN TWO PROCESS SIGNALS AND DISPLAY IN ENGINEERING UNITS.
  • Page 2 OMEGA: PURCHASED. 1. P.O. number to cover the COST of the CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as 2. Model and serial number of the product repair, a "Basic Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity;...