Omega DP18 series Instruction Sheet

Omega DP18 series Instruction Sheet

Option aph1 analog peak hold option

Advertisement

An O M EG A Tech n ol ogies C om p an y
DP18 Series
Option APH1

Analog Peak Hold Option

INSTRUCTION
SHEET
PUSHBUTTON RESET OF FUNCTION HOLD
DECIMAL POINT, POINTER THAT THE
"HOLD" FUNCTION, IS ACTIVATED.
SIGNAL
INPUT
ANALOG OUTPUT
(option)
DISPLAY
2.000
READING
1.500
1.000
500
300
M2122/1294
ANALOG PEAK HOLD OPTION
OPTION APH1 : Incompatible with options R1, R2, BCD, 232

FRONT VIEW

REAR VIEW

10
1
POWER
5
9.5
14
30
THIS SYSTEM FOR MAXIMUM READING, IS AVAILABLE FOR
THOSE APPLICATIONS WHERE A SUDDEN SIGNAL DECREASE
IS PRODUCED. FOR EXAMPLE: TEST SAMPLES SYSTEM,
PRESSURE TESTS, COMPRESSION, STRENGTH, VACUUM,
ETC.
THIS SYSTEM OPERATES WHEN THE SIGNAL INPUT
DECREASES, GENERATING AN ORDER THAT BLOCKS
INSTANTANEOUSLY, THE PRESENT READING IN THE DISPLAY,
ACTING ON THE "HOLD" FUNCTION. THE DECIMAL POINT,
PLACED TO THE RIGHT SIDE, ILLUMINATES, (1XXX.), WHEN THE
DISPLAY IS INDICATING A PEAK (MAXIMUM VALUE).
PRESSING THE PUSHBUTTON RESET, THE FUNCTION "HOLD"
DISAPPEARS, AND THE DISPLAY CHANGES TO READ THE
CORRESPONDING VALUE OF THE INPUT SIGNAL.
THE TIME PERIOD, DURING WHICH THE "HOLD" FUNCTION
REMAINS ACTIVATED, DEPENDS ON THE SIGNAL INPUT
VARIATION, (DIFFERENCE BETWEEN THE PEAK VALUE AND
THE VALUE CORRESPONDING TO THE SUDDEN SIGNAL
DECREASE).
(POSITIVE FOR DC POWER)
(NEGATIVE FOR DC POWER)
EXAMPLE : MAXIMUM VALUE OF 1.500 COUNTS,
THAT DECREASES TO 300 COUNTS.
THE TIME THAT THE READING OF 1.500 COUNTS,
WILL REMAIN ON THE DISPLAY, WILL BE :
23 - 5 = 18 MINUTES
18.5
23
CCD1294APC1B

SPECIFICATIONS

MINUTES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP18 series and is the answer not in the manual?

Questions and answers

Summary of Contents for Omega DP18 series

  • Page 1 An O M EG A Tech n ol ogies C om p an y DP18 Series Option APH1 Analog Peak Hold Option INSTRUCTION SHEET M2122/1294 ANALOG PEAK HOLD OPTION OPTION APH1 : Incompatible with options R1, R2, BCD, 232 SPECIFICATIONS...
  • Page 2 Authorized Return (AR) number immediately upon phone or written request. Upon Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA examination by OMEGA, if the unit is found to be defective it will be repaired or replaced Customer Service: 1-800-622-2378 / 1-800-622-BEST at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN tampered with or shows evidence of being damaged as a result of excessive corrosion;...

Table of Contents