Kenwood TK-2170ST Service Manual page 45

Table of Contents

Advertisement

Common Section
Item
Condition
1. Setting
1) BATT terminal voltage : 7.5V
2) SSG standard modulation
[Wide]
MOD : 1kHz, DEV : 3kHz
[Narrow]
MOD : 1kHz, DEV : 1.5kHz
2. VCO lock
[Panel test mode]
voltage
1) CH-Sig : 3-1
• RX
2) CH-Sig : 2-1
• TX
[Panel tuning mode] LPWR*
3) CH-Sig : 3-1
PTT : ON
4) CH-Sig : 2-1
PTT : ON
* TX can be continued on unlock condition in panel tuning mode.
Transmitter Section
Item
Condition
1. Frequency
1) Adj item : [FREQ_]
adjust
Adjust : [✳✳✳]
CH-Sig : 3-1
PTT : ON
2. High power
1) Adj item : [HPWR_]
adjust
Adjust : [✳✳✳]
2) Adj item : [H.PWR_] →
[H.P.WR_] → [H.P.W.R_] →
[H.P.W.R._] → [H.P.W.R._.]
Adjust : [✳✳✳]
PTT : ON
3. High power
[Panel test mode]
check
1) CH-Sig : 1-1
PTT : ON
2) CH-Sig : 2-1
PTT : ON
3) CH-Sig : 3-1
PTT : ON
4. Low power
1) Adj item : [LPWR_]
adjust
Adjust : [✳✳✳]
2) Adj item : [L.PWR_] →
[L.P.W.R_] → [L.P.W.R._.]
Adjust : [✳✳✳]
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
TX-RX TC502 3.8V
(A/4)
DVM
TX-RX CV
(A/4)
TX-RX TC501 3.8V
(A/4)
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter Panel
ANT
Panel
Power meter
Ammeter
Panel
TK-2170/2170ST
Adjustment
Parts
Method
± 0.1V
Check
0.6V or more
± 0.1V
Check
0.6V or more
Adjustment
Parts
Method
Selector High frequency
Note : After replacing the
± 50Hz
knob
TCXO (X501) align frequency.
± 0.1W
5.0W
1.8A or less
Check
4.5~5.5W
1.9A or less
± 0.1W
Selector 1.0W
knob
0.9A or less
Specifications/Remarks
Specifications/Remarks
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-2170

Table of Contents