Electrolux FMV156EMC Service Manual page 17

Table of Contents

Advertisement

PROCEDURE
LETTER
cAUtIoN: IF tHE tEMPERAtURE FUSE INDIcAtES AN oPEN cIRcUIt At RooM
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
cAUtIoN: IF t HE t EMPERAtURE FUSE INDIcAtES AN oPEN cIRcUIt At RooM t EMPERAtURE,
F
PRIMARY INTERLOCK SWITCH TEST
1. Disconnect the power supply cord, and then remove outer case.
. open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the switch and connect the ohmmeter to the common (coM.) and normally open (No) terminal
of the switch. the meter should indicate an open circuit with the door open and a closed circuit with
the door closed. If improper operation is indicated, replace the secondary interlock switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
5. Reconnect all leads removed from
components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after
the outer case is installed.
8. Run the oven and check all functions.
G
PRIMARY INTERLOCK SYSTEM TEST
DooR SENSING SWItcH
1. Disconnect the power supply cord, and then remove outer case.
. open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the switch and connect the ohmmeter to the common (coM.) and normally open (No)
terminal of the switch. the meter should indicate an open circuit with the door open and a closed
circuit with the door closed. If improper operation is indicated, replace the door sensing switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
NotE: If the door sensing switch contacts fail in the open position and the door is closed, the cooling
fan motor, stirrer motor and oven light will be activated by RY1.
TEST PROCEDURES
tEMPERAtURE, REPlAcE tEMPERAtURE FUSE.
REPlAcE tEMPERAtURE FUSE.
COMPONENT TEST
17
FMV156EMC

Advertisement

Table of Contents
loading

This manual is also suitable for:

S05m256fm56em

Table of Contents