PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE EXPO-
SURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: () interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave genera-
tion and transmission systems shall be repaired, replaced, or adjusted by procedures described in this
manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
Before servicing an operative unit, perform a microwave emission check as per the Microwave
Measurement Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact ELECTROLUX CANADA
CORPORATION immediately.
If the unit operates with the door open, service person should ) tell the user not to operate the oven
and 2) contact ELECTROLUX CANADA CORPORATION and NHW, CANADA or ELECTROLUX
HOME PRODUCTS, INC. and FOOD & DRUG ADMINASTRATION centers for Devices & Radio-
logical Health immediately.
In the USA, please contact the Food and Drug Administration's Center for Devices and Radiologi-
cal Health immediately.
Service personnel should inform ELECTROLUX CANADA CORPORATION or ELECTROLUX HOME
PRODUCTS, INC. of any certified unit found with emissions in excess of 4mW/cm
the unit should be instructed not to use the unit until the oven has been brought into compliance.

BEFORE SERVICING