STORAGE
7.5 REMOVAL FROM
STORAGE
• Remove protective cloths, covers, and caps from
the engine.
• Clean protectant from exposed metal parts and
electrical components.
• Tighten the alternator belt.
• Check fluid levels and fill as needed.
• Connect the battery.
• Connect the fuel supply and open fuel valves.
• Start the engine and allow it to run for several
minutes without load. Check for leaks and watch
for signs of abnormal operation.
T
NOTE:
The engine may smoke when started for the first time
after being taken out of storage. This is normal and
occurs as the engine burns away the protective oil
coating inside the cylinders.
• Check oil pressure and fuel pressure gauges to
make sure that the engine is operating normally.