Entry – Used to confirm Set Point changes, cancel
inputs, advance day, and change AM/PM.
Setpoints – For setting chilled liquid temperature,
chilled liquid range, remote reset temperature range.
Clock – Used to set time, daily or holiday start/stop
schedule and manual override for servicing.
Print – Used to display or print operating data or sys-
tem fault shutdown history for last six faults. Printouts
through an RS-232 port via a separate printer.

Program

For setting low leaving liquid temperature cutout, 300
to 600 second anti-recycle timer, average motor current
unload point, liquid temperature setpoint reset signal
from YORK ISN or building automation system.
Additional functions (password protected) for program-
ming by a qualified service technician:
Cutouts for low and high ambient, low suction pressure
and high discharge pressure, refrigerant type, high dis-
charge pressure unload setpoint.

ACCESSORIES AND OPTIONS

Multiple Point Power Connection (Standard)

Standard field power wiring connection on all models
is Multiple Point Power Connection. Field provided
power supply circuits, with appropriate branch circuit
protection, are connected to factory provided terminal
blocks, non-fused disconnect switches or circuit breakers
with lockable external handles located in the two power
compartments.
Single-Point Power Connection with Individual
Circuit Protection
A single-point supply circuit with field provided protec-
tion is connected to a factory provided terminal block
or non-fused disconnect switch located in the options
compartment. Factory wiring is provided from the ter-
minal block or disconnect switch to factory supplied
internal branch circuit breakers with lockable external
handles in the power compartments.
24
Single-Point Power Connection with Combined
Circuit Protection
A single-point supply circuit with field provided protec-
tion is connected to a factory provided circuit breaker
with lockable external handle located in the options
compartment. Factory wiring is provided from the circuit
breaker to factory supplied terminal blocks in the power
compartments.
Single-Point Power Connection without Circuit
Protection
A single-point supply circuit with field provided protec-
tion is connected to a factory provided terminal block
or non-fused disconnect switch located in the options
compartment. Factory wiring is provided from the ter-
minal block or disconnect switch to factory supplied
terminal blocks in the power compartments.

Control Circuit Terminal Block

A 120V, 20A control circuit power terminal strip located
in the control panel to accept a field provided control
power supply, rather than the standard factory mounted
control circuit transformer. The supply with appropriate
branch circuit protection in accordance with applicable
Local codes, provides the unit control circuit power
supply via the panel mounted Emergency Stop Switch.

Building Automation System (BAS) Interface

Provides a means to reset the leaving chilled liquid
temperature or percent full load amps (current limiting)
from the BAS (Factory-mounted):
Printed circuit board to accept 4 to 20mA, 0 to 10VDC,
or dry contact closure input from the BAS.
A YORK ISN Building Automation System can pro-
vide a Pulse Width Modulated (PWM) signal direct to
the standard control panel via the standard on-board
RS485 port.

Condenser Coil Protection

The standard condenser coils have Aluminum fins, cop-
per tubes, and galvanized steel supports for generally
adequate corrosion resistance. However, these materials
are not adequate for all environments.