Beijer Electronics EXTER K100 Installation Manual

Beijer Electronics EXTER K100 Installation Manual

Hide thumbs Also See for EXTER K100:

Advertisement

Quick Links

EXTER™ K100
Installation manual
English
MAEN773D, 2008-05

Advertisement

Table of Contents
loading

Summary of Contents for Beijer Electronics EXTER K100

  • Page 1 EXTER™ K100 Installation manual English MAEN773D, 2008-05...
  • Page 2 Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document. Read the entire installation manual prior to installing and using this equipment.
  • Page 3: Table Of Contents

    5 Operator Panel Drawings ..............17 5.1 Communication Ports..............17 5.2 EXTER K100 Outline ..............18 5.3 EXTER K100 Text Strip ..............19 6 Additional Installation Tips..............21 6.1 Grounding the Operator Panel ............21 6.2 Ethernet Connection in the Panel ........... 22 6.3 To Achieve Better EMC Protection ..........
  • Page 4 Table of Contents Beijer Electronics, MAEN773D...
  • Page 5: Safety Precautions

    – For use on a flat surface of a type 4X enclosure indoor use only. – To make wiring connections to the power supply connector, use an AWG 28-12 cable and a tightening torque of min. 0.5 Nm. Beijer Electronics, MAEN773D...
  • Page 6: General

    – Separate the high voltage, signal and supply cables. – Make sure that the voltage and polarity of the power source is correct before connecting the product to the power outlet. – Peripheral equipment must be appropriate for the application and location. Beijer Electronics, MAEN773D...
  • Page 7: During Use

    1.6 Dismantling and Scrapping – The operator panel or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. Beijer Electronics, MAEN773D...
  • Page 8 Safety Precautions Beijer Electronics, MAEN773D...
  • Page 9: Installation

    If access to the text strips is needed, add extra space in the left corners. For text strip 3.5 mm (0.14 inch) 6.5 mm (0.26 inch) Beijer Electronics, MAEN773D...
  • Page 10 - Ensure that the voltage and polarity of the power source is correct. Power Controller RS422/RS485 24V DC 24V DC RS232 Ethernet 5. Carefully remove the laminated film over the operator panel display, to avoid static electricity that could damage the panel. Beijer Electronics, MAEN773D...
  • Page 11: Mode Switches

    – Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. Caution When using a compact flash card, do not remove the card when the busy indicator is illuminated. Beijer Electronics, MAEN773D...
  • Page 12 Installation Beijer Electronics, MAEN773D...
  • Page 13: Technical Data

    Technical Data Technical Data Parameter EXTER K100 Front panel, W x H x D 382 x 252 x 6 mm Mounting depth 58 mm (158 mm including clearance) Front panel seal IP 66 Rear panel seal IP 20 Keyboard material Membrane switch keyboard with metal domes.
  • Page 14 Technical Data Beijer Electronics, MAEN773D...
  • Page 15: Chemical Resistance

    42 115 Part 2 to the following chemicals without visible change: Acetonitrile Phosphoric acid (<30%) Diesel Downey / Lenor Ajax / Vim in solution Ethanol Potassium ferricyanide Glycerine Potassium hydroxide (<30%) Alkalicarbonate solution Glycol Pure Turpentine Ammonia (<40%) Beijer Electronics, MAEN773D...
  • Page 16: Touch Screen Surface

    5 hours 4.2.3 Autoflex EB It is recommended to use the Autoflex EB touch display protection film, that can be ordered from Beijer Electronics. Solvent Resistance Autoflex EB withstands exposure to the same chemicals as Autotex F157 or F207 according to section Autotex F157/F207.
  • Page 17: Operator Panel Drawings

    Operator Panel Drawings Operator Panel Drawings 5.1 Communication Ports RS-232 RS-422 RS-485 RS-422/485 Ethernet Drawing No. S-5005, Date 2004-10-27 Beijer Electronics, MAEN773D...
  • Page 18: Exter K100 Outline

    Operator Panel Drawings 5.2 EXTER K100 Outline Drawing No. S-5083, Date 2004-10-14 (Revision date 2005-02-03) Beijer Electronics, MAEN773D...
  • Page 19: Exter K100 Text Strip

    Operator Panel Drawings 5.3 EXTER K100 Text Strip Drawing No. S-5077, Date 2004-09-24 Beijer Electronics, MAEN773D...
  • Page 20 Operator Panel Drawings Beijer Electronics, MAEN773D...
  • Page 21: Additional Installation Tips

    Multi-wire conductors are better than single wire conductors with the same area. A braided conductor wire with the same area is even better. The best is a short, thick grounding braid. Beijer Electronics, MAEN773D...
  • Page 22: Ethernet Connection In The Panel

    4. A more elegant method is to expand the shielded Ethernet cabling with a piece of unshielded Ethernet cable. 5. You can ground the shield via an external 0.1 uF/250 V plastic capacitor. This will connect the HF transients to the ground. Beijer Electronics, MAEN773D...
  • Page 23: To Achieve Better Emc Protection

    Additional Installation Tips 6.3 To Achieve Better EMC Protection – Initially, use the original cabling from Beijer Electronics primarily. – Use shielded cables for RS232 communication. – Use twisted pair and shielded cabling for RS422 and RS485. – Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link, CAN, Device Net etc.
  • Page 24: Ambient Temperature

    The loss effect drops from e.g. 25 W to only 5 W. The operator panel’s loss effect = supply voltage x current. Virtually no power goes to external users and no loss effects due to inputs. Beijer Electronics, MAEN773D...
  • Page 25: Safety

    –Transients on the 24 V feed are connected to the ground. –No risk that the 24 V feed is at a high level in relationship to the ground. This is not unusual since there is high static electricity. Beijer Electronics, MAEN773D...
  • Page 26: Galvanic Isolation

    24 V feed, disturbances and grounding currents from the 0 V on the 24 V side will disrupt communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Beijer Electronics, MAEN773D...
  • Page 27: Cable And Bus Termination Rs485

    3. Connect two 1k/0.25 W resistors in the 25-pole D-sub contact. Set jumper pins 6-19. 4. Use CAB8. It offers the option of bus termination with pull-up/-down. It is also easy to connect the bus cable via the screw terminal block. Beijer Electronics, MAEN773D...
  • Page 28 HEAD OFFICE SUBSIDIARIES SWEDEN GERMANY Beijer Electronics Products AB Elektronik-Systeme Lauer GmbH & Co. KG Beijer Electronics Inc. Box 426 Kelterstraße 59 939 N. Plum Grove Road, Suite F SE-201 24 Malmö, Sweden 72669 Unterensingen, GERMANY Schaumburg, IL 601 73, USA...